Commissioning and configuration
Leuze electronic
BCL 548
i
165
TNT
35/7-2
4
V
10.11.2 Module 53 – Segmentation via fixed positions
PROFINET-IO module identifier
Module-ID 1053
Submodule-ID 1
Description
The module activates the segmentation via fixed positions. The parameters specify the iden-
tifiers to be searched for, the output mode, and the positions.
Parameter
Parameter
Description
Addr
.
Data type
Value range
Default
Unit
Identifier list
Identifier 1
The identifier string is used for the identifier list
and the filtering according to the segmenta-
tion.
0
STRING
5 characters null
terminated
1 … 5 bytes of
ASCII characters
‘*‘
-
Identifier 2
See identifier 1.
5
STRING
5 characters null
terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 3
See identifier 1.
10
STRING
5 characters null
terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 4
See identifier 1.
15
STRING
5 characters null
terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 5
See identifier 1.
20
STRING
5 characters null
terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier output
Output with iden-
tifier
If this switch is not set, the output of the iden-
tifiers is suppressed. In this case, only the data
values belonging to the identifiers are dis-
played.
25.0
Bit
0: Output of the
identifiers is
suppressed.
1: Identifiers are
output.
1
-
Output delimiter
This delimiter, if not equal to 0, is inserted
between the identifier and the associated data
value in the output.
26
UNSIGNED8
0 … 127
0
-
Fixed positions
Start position of
the 1st identifier
Specifies the position of the first character of
the first identifier in the data string of the bar
code.
The first character in the bar code has position
1. If the parameter is = 0, it is deactivated.
27
UNSIGNED8
0 … 127
0
-
Start position of
the 1st data
value
Specifies the position of the first character of
the first data value in the data string of the bar
code.
The first character in the bar code has position
1. If the parameter is = 0, it is deactivated.
28
UNSIGNED8
0 … 127
0
-
Start position of
the 2nd identifier
Specifies the position of the first character of
the second identifier in the data string of the
bar code.
The first character in the bar code has position
1. If the parameter is = 0, it is deactivated.
29
UNSIGNED8
0 … 127
0
-
Table 10.32:
Parameters for module 53