Specifications
Leuze electronic
BCL 504
i
37
TNT 35/7-24V
5.2.3
Line scanner with deflection mirror and heating
Technical data same as for line scanner without heating with the following differences:
Min. conductor cross-section
Conductor cross-section of at least 0.75mm² for the supply-voltage supply line.
Wiring through of the voltage supply to multiple heating devices is
not
permissi-
ble.
Standard, M12 ready-made cable
not
usable
(insufficient cable cross-section)
Environmental data
Operating temperature range
-35°C … +40°C
Storage temperature range
-20°C … +70°C
Type
BCL 504
i
PROFIBUS DP
Type
Oscillating-mirror scanner with heating
Table 5.5:
Specifications of the BCL 504
i
oscillating-mirror scanners with heating
Type
BCL 504
i
PROFIBUS DP
Type
Deflection mirror scanner with heating
Optical data
Useful opening angle
max. 50°
Max. adjustment range
±10°(adjustable via display or software)
Electrical data
Operating voltage
24VDC ±20%
Power consumption
max. 75W
Structure of the heating
Housing heating and separate heating of the optics glass
Warmup time
Min. 30min at +24VDC and an ambient temperature of -35°C
Min. conductor cross-section
Conductor cross-section of at least 0.75mm² for the supply-voltage supply line.
Wiring through of the voltage supply to multiple heating devices is
not
permissi-
ble.
Standard, M12 ready-made cable
not
usable
(insufficient cable cross-section)
Environmental data
Operating temperature range
-35°C … +40°C
Storage temperature range
-20°C … +70°C
Table 5.6:
Specifications of the BCL 504
i