Commissioning and configuration
176
BCL 504
i
Leuze electronic
10.15 Special Functions
10.15.1 Module 90 – Status and control
This module supplies various BCL 504
i
status information to the PROFIBUS master.
Various functions of the BCL 504
i
can be controlled via the master's output data.
Parameters
None
Input data
Input data length
1 byte
Output data
None
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
Reserved
Free
0.0
Bit
0
-
AutoRefl state
Signal state of the AutoRefl mod-
ule
0.1
Bit
0: Reflector is
recognised
1: Reflector is
hidden
1
-
Auto Control result
Indicates whether the result of
the AutoControl function was a
good or bad reading.
0.2
Bit
0: Quality good
1: Quality bad
0
-
Reserved
Free
0.3
Bit
0
-
RefCode compari-
son state 1
The signal indicates whether the
decoded barcode corresponds to
the reference code with regard to
the comparison criteria as
defined in the comparison func-
tion 1. If it matches, the value 1 is
output.
0.4
…
0.5
Bit
0: Not equal
1: Equal
2: Unknown
2
-
RefCode compari-
son state 2
The signal indicates whether the
decoded barcode corresponds to
the reference code with regard to
the comparison criteria as
defined in the comparison func-
tion 2. If it matches, the value 1 is
output.
0.6
…
0.7
Bit
0: Not equal
1: Equal
2: Unknown
2
-
Table 10.59:
Input data for module 90 – Status and control