Commissioning and configuration
Leuze electronic
BCL 504
i
169
TNT 35/7-24V
10.13 Data output
10.13.1 Module 80 – Sorting
Description
Module to support the sorting of the output data.
Parameters
Parameter length
3 byte
Input data
None
Output data
None
Parameter
Description
Addr. Data type
Value range
Default
Unit
Sort crite-
rion 1
Specifies the crite-
rion according to
which sorting takes
place.
0.0 …
0.6
BitArea
0: No sorting
1: Sorting according to scan number
2: Sorting according to position in the
scanning beam
3: Sorting according to the oscillating mir-
ror position
4: Sorting according to the decoding
quality
5: Sorting according to the barcode
length
6: Sorting according to the code type
number
7: Sorting according to the decoding
direction
8: Sorting according to the barcode con-
tent
9: Sorting according to time
10: Sorting according to scanning duration
11: Sorting according to the code list (in
which the enabled barcodes are listed)
12: Sorting according to the identifier list
0
-
Sort direc-
tion 1
Specifies the sort-
ing direction.
0.7
Bit
0: In ascending order
1: In descending order
0
-
Sort crite-
rion 2
Specifies the crite-
rion according to
which sorting takes
place.
1.0
…
1.6
BitArea
See sorting criterion 1
0
-
Sort direc-
tion 2
Specifies the sort-
ing direction.
1.7
Bit
See sorting direction 1
0
-
Sort crite-
rion 3
Specifies the crite-
rion according to
which sorting takes
place.
2.0
…
2.6
BitArea
See sorting criterion 1
0
-
Sort direc-
tion 3
Specifies the sort-
ing direction.
2.7
Bit
See sorting direction 1
0
-
Table 10.54:
Parameters for module 80