Commissioning and configuration
166
BCL 504
i
Leuze electronic
10.12.9 Module 74 – SWIO status and control
Description
Module for handling switching input and switching output signals.
Parameters
None
Input data
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
State 1
Signal state of switching input or
output 1
0.0
Bit
0,1
0
-
State 2
Signal state of switching input or
output 2
0.1
Bit
0,1
0
-
State 3
Signal state of switching input or
output 3
0.2
Bit
0,1
0
-
State 4
Signal state of switching input or
output 4
0.3
Bit
0,1
0
-
Comparison state
switching output 1
(Event Counter)
Indicates whether the event
counter has exceeded the set
comparative value.
The bit is reset to the init. value
by resetting the event counter.
1.0
Bit
0: Not exceeded
1: Exceeded
0
-
Switching output 1
Comparison state
toggle bit
(Event Counter)
If "SWOUT switches several
times" was configured as com-
parison mode, this bit is toggled
each time the event counter is
exceeded.
The bit is reset to the init. value
by resetting the event counter.
1.1
Bit
0
→
1: Event
counter
exceeded
1
→
0: Event
counter
exceeded
again
0
-
Comparison state
switching output 2
(Event Counter)
Indicates whether the event
counter has exceeded the set
comparative value.
The bit is reset to the init. value
by resetting the event counter.
1.2
Bit
0: Not exceeded
1: Exceeded
0
-
Switching output 2
Comparison state
toggle bit
(Event Counter)
If "SWOUT switches several
times" was configured as com-
parison mode, this bit is toggled
each time the event counter is
exceeded.
The bit is reset to the init. value
by resetting the event counter.
1.3
Bit
0
→
1: Event
counter
exceeded
1
→
0: Event
counter
exceeded
again
0
-
Comparison state
switching output 3
(Event Counter)
Indicates whether the event
counter has exceeded the set
comparative value.
The bit is reset to the init. value
by resetting the event counter.
1.4
Bit
0: Not exceeded
1: Exceeded
0
-
Table 10.52:
Input data for module 74 Input/output status and control