Commissioning and configuration
158
BCL 504
i
Leuze electronic
10.12.5 Module 70 – Switching input/output SWIO1
Parameters
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Function
This parameter defines
whether I/O 1 functions as an
input or as an output.
0.0
Bit
0: Input
1: Output
0
-
Mode of operation for configuration as an output
DC bias level
The parameter defines the DC
bias level of the switching out-
put and, thus, simultaneously
whether the output is low-
active (0) or high-active (1).
0.1
Bit
0: LOW (0V)
1: HIGH (+Ub)
0
-
Reserved
Free
0.2 … 0.7
Start-up delay
With this parameter, the output
pulse may be delayed by a set
time period.
1
UNSIGNED16
0 … 65535
0
ms
Switch-on
time
The parameter defines the
switch-on time period for the
switching output. If the value is
0, the signal is static.
3
UNSIGNED16
0 … 1300
400
ms
Switch-on
function 1
This parameter specifies an
event which can set the switch-
ing output.
5
UNSIGNED8
switch-off
functions"
on page 157
0
-
Switch-on
function 2
This parameter specifies an
event which can set the switch-
ing output.
Switch-on function 1 and
switch-on function 2 are OR
linked.
6
UNSIGNED8
switch-off
functions"
on page 157
0
-
Switch-off
function 1
This parameter specifies an
event which can reset the
switching output.
7
UNSIGNED8
switch-off
functions"
on page 157
0
-
Switch-off
function 2
This parameter specifies an
event which can reset the
switching output.
Switch-off function 1 and
switch-off function 2 are OR
linked.
8
UNSIGNED8
switch-off
functions"
on page 157
0
-
Comparative
value
(Event Coun-
ter)
If the number of activation
events of the selected switch-
on function reaches this com-
parative value, the switching
output is activated. A deactiva-
tion event of the selected
switch-off function resets the
counter.
9
UNSIGNED16
0..65535
0
-
Compare
mode
(Event Coun-
ter)
Specifies whether the switch-
ing output switches only on
parity (once) or also in the
event of greater or equal to
(multiple times) after the com-
parative value is reached.
11
UNSIGNED8
0: SWOUT
switches
once
1: SWOUT
switches
several
times
0
-
Table 10.48:
Parameters for module 70 – Input/Output 1