Commissioning and configuration
156
BCL 504
i
Leuze electronic
Switch-on time ton
This parameter specifies the min. activation duration for the selected input function in ms.
The actual activation duration is calculated from the switch-on time as well as the switch-off
delay.
Figure 10.6: Switch-on time in input mode
Switch-off delay td_off
This parameter specifies the duration of the switch-off delay in ms.
Figure 10.7: Switch-off delay in input mode
Input signal
Output signal
Start-up delay td_on
Switch-on
time ton
Switch-off delay td_off
Input signal
Output signal
Start-up delay td_on
Switch-on time ton
Switch-off delay td_off