Commissioning and configuration
150
BCL 504
i
Leuze electronic
10.11.4 Module 63 – Alignment
Description
The module defines input and output data for the alignment mode of the BCL 504
i
. The
alignment mode is used for easy alignment of the BCL 504
i
with the barcode. Using the
transmitted decoding quality as a percentage, the optimum alignment can be easily
selected. This module should not be used in connection with module 81 (AutoReflAct) as
this may cause malfunctions.
Parameters
None
Input data
Input data length
1 byte
Output data
Output data length
1 byte
Input data
Description
Addr. Data type
Value range
Init
value
Unit
Decoding quality
Transmits the current decoding quality
of the barcode located in the scanning
beam
0
Byte
0 … 100
0
Percent-
age
Table 10.42:
Input data for module 63
Output data
Description
Addr.
Data type
Value range
Init
value
Unit
Alignment mode
Signal activates and deactivates
the alignment mode for optimum
alignment of the BCL 504
i
with
the barcode
0.0
Bit
0 -> 1: On
1 -> 0: Off
0
-
Table 10.43:
Output data for module 63