Commissioning and configuration
Leuze electronic
BCL 504
i
149
TNT 35/7-24V
10.11.3 Module 62 – Display
Description
Set in this module are general parameters and parameters related to operation and the
display.
Parameters
Parameter length
3 byte
Input data
None
Output data
None
Notice!
This module overwrites the local display settings. Following activation of this module, the
language selection, the setting for password protection and the specified password set in
this module take effect.
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Language
selection
Language selection for the display
A language which was selected via the
display is overwritten by this parameter.
0.0 …
0.2
Bit
1: English
2: German
3: Italian
4: French
5: Spanish
0
-
Display illu-
mination
Off after 10min., or permanently on.
0.3
Bit
0: Off after
10min.
1: Perma-
nently on
0
-
Display con-
trast
Contrast setting of the display. The
contrast changes under extreme ambi-
ent temperature and can be adjusted
with this parameter.
0.4 …
0.5
Bit
0: Light
1: Medium
2: Strong
1
-
Password
protection
Password protection on/off.
0.7
Bit
0: OFF
1: ON
0
-
Password
Password specification.
Password is only active if password
protection is on.
1 … 2
UNSIGNED16 0000 … 9999
0000
-
Table 10.41:
Parameters for module 62