Commissioning and configuration
Leuze electronic
BCL 504
i
147
TNT 35/7-24V
10.11 Device Functions
10.11.1 Module 60 – Device status
Description
The module contains the display of the device status as well as control bits for triggering a
reset or putting the device into standby mode.
Parameters
None
Input data
Input data length
1 byte
Output data
Output data length
1 byte
Notice!
When resetting the data (see Module 10 – Activations), the input data of this module is not
deleted.
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
Device status
This byte represents
the device status
0
UNSIGNED8
0: Device is ready
1: Initialisation
10: Standby
11: Service
12: Diagnosis
13: Parameter enabled
0x80:Error
0x81:Warning
0
-
Table 10.38:
Input data for module 60
Output data
Description
Addr.
Data type
Value range
Init
value
Unit
System reset
The control bit triggers a system
reset
1)
if the level changes from 0
to 1
1)
Analogous to command H, activation of this bit triggers a restart of all electronics, incl. a
restart of the PROFIBUS stack.
0.6
Bit
0: Run
0 -> 1: Reset
0
-
Standby
Activates the standby function
0.7
Bit
0: Standby off
1: Standby on
0
-
Table 10.39:
Output data for module 60