Commissioning and configuration
Leuze electronic
BCL 504
i
135
TNT 35/7-24V
10.8.12 Module 39 – Number of digits
Description
The module defines input data for the communication of the number of digits of the currently
transmitted barcode.
Parameters
None
Input data
Input data length
1 byte
Output data
None
10.8.13 Module 40 – Code type
Description
The module defines the input data for the communication of the code type of the currently
transmitted barcode.
Parameters
None
Input data
Input data length
1 byte
Output data
None
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
Number of digits
Number of digits of the transmit-
ted barcode
0
UNSIGNED8
0 … 48
0
-
Table 10.29:
Input data for module 39
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
Code type
Code type of the
transmitted bar-
code
0
UNSIGNED8
0: 0: No code
1: 2/5 Interleaved
2: Code39
6: UPC, UPCE
7: EAN8, EAN13
8: Code128, EAN128
10: EAN Addendum
11: Codabar
12: Code93
13: RSS-14
14: RSS Limited
15: RSS Expanded
0
-
Table 10.30:
Input data for module 40