Commissioning and configuration
Leuze electronic
BCL 504
i
115
TNT 35/7-24V
10.6
Decoder modules
10.6.1
Modules 1-4 – Code table extensions 1 to 4
Description
The modules extend the code type tables of the device parameters and permit the additional
definition of further 4 code types together with the respective number of digits.
Parameters
Parameter
Description
Rel. addr.
Data type
Value range
Default
Unit
Code type
Released code type; no
code means that all sub-
sequent code tables are
also deactivated.
The valid number of dig-
its also depends on the
code type.
0.0 … 0.5
BitArea
0: 0: No code
1: 2/5 Interleaved
2: Code39
3: Code32
6: UPC, UPCE
7: EAN8, EAN13
8: Code128
10: EAN Addendum
11: Codabar
12: Code93
13: RSS-14
14: RSS Limited
15: RSS Expanded
0 -
Number-of-digits
mode
Interpretation of the
number of digits
1.6
Bit
0: Enumeration
1: Range
0
-
Digits 1
1)
Decodable number of
digits; in the case of a
range, this number
defines the lower limit.
1.0 … 1.5
UNSIGNED8
0 … 63
0
-
Digits 2
Decodable number of
digits; in the case of a
range, this number
defines the upper limit.
2
UNSIGNED8
0 … 63
0
-
Digits 3
Decodable number of
digits in the enumeration
mode.
3
UNSIGNED8
0 … 63
0
-
Digits 4
Decodable number of
digits in the enumeration
mode.
4
UNSIGNED8
0 … 63
0
-
Digits 5
Decodable number of
digits in the enumeration
mode.
5
UNSIGNED8
0 … 63
0
-
Table 10.7:
Parameters for modules 1-4