Important Parameters
Leuze electronic
BCL 8
55
TNT
35/7-2
4
V
Reflector polling
Reflector polling (
autoReflAct
) is an operating mode in which no external sensor is required
for triggering. The scanner is activated and deactivated with the aid of a reflector (see Acces-
sories) which must be mounted in the scanning range of the BCL 8.
For simple alignment in
autoReflAct
mode, please select the
AutoReflAct
Wizard.
Once called up, the wizard attempts to establish a connection to the connected BCL 8. If this
is successfully, please select one of the four reflector polling modes under "Mode" from the
menu which then appears. A screen similar to the following appears:
Figure 10.10: AutoReflAct Wizard
Upon activation of the "Search" button, the BCL 8 scans its reading field and attempts to find
a reflector. To do this, the reflector must be positioned in the reading field of the scanner.
After a reflector has been detected, it passes on the start position of the reflector in its
reading field.
By clicking "OK", the values are stored in the scanner and in BCLConfig.
The scanner is now ready for the AutoReflAct operating mode.
Attention!
If other reflective objects are located in the reading window of the scanner besides the re-
flector, the application is to be checked carefully, because these reflective parts could pos-
sibly cause a mistrigger in the scanner!
Notice!
The reflector should be mounted at a distance of max. 300mm from the BCL 8.