Accessories / Order Designation
Leuze electronic
BCL 8
25
TNT
35/7-2
4
V
5.2.4
MA 8.1 - BCL - connecting the BCL 8 to the MA 8.1
Figure 5.1:
MA 8.1 - Pin assignment BCL
Attention!
Protection class IP 67 is achieved only if the connectors and caps are screwed into place!
The BCL 8 is connected to the MA 8.1 via the connection cable KB 008-1000/2000/3000
(AA/AR). The voltage supply is connected via the
PWR IN HOST/RS 232
socket.
Attention!
It is absolutely necessary to connect functional earth, since all electrical interference (EM
pick-up) is discharged via the functional earth connection.
BCL (5-pin socket, A-coded)
Pin
Name
Remark
1
VIN
Supply voltage for BCL 8
+4.9 … +5.4VDC
2
TXD
RS 232 transmission line
3
GND
Supply voltage 0VDC
4
RXD
RS 232 receiving line
5
SWIN/
SWOUT
Programmable switching input/output of the
BCL 8
Thread
FE
Functional earth (housing)
1
2
3
4
5
RXD
VIN
GND
SWIN/SWOUT
TXD
BCL 8
M12 socket
(A-coded)