Important Parameters
Leuze
electronic
54
BCL 21/22
Leuze electronic
10
Important Parameters
10.1
Code menu
Figure 10.1: Standard setting of the code menu
Notice!
If the code EAN128 is to be read, 3 additional characters are to be set for the code identifier.
Code table
Here, the codes which are to be decoded are set. We recommend enabling
only the code types which are to actually be read with the corresponding
element numbers.
Important: Code 1 must always be selected. If multiple code types are to
be used, set in sequential order: Code 1, Code 2, …
Number Of
Digits
In the field Element number, up to 3 element entries may be entered.
An area is represented by a dashed line:
e.g. 4-40 digits.
With 2 or 3 different element entries
by a comma: e.g:
8,13 digits
The combination is also possible,
but the range must be specified first:
e.g.: 4-10,20 digits
Properties
Behind the "Properties" button, to the right of the respective code, the
code-specific settings, such as the check digit, can be selected.
Number of bar
codes
Here, the number of the bar codes to be decoded within a read cycle (one
reading gate) is set.
Содержание BCL 21