6.3.3
Wire Lengths and Shielding
The following maximum lengths for wires and the type of shielding to be used must be
observed:
Table 6.15:
Wire Lengths and Shielding
6.4
Disassembling, Packing, Disposing
Repacking
For later re-use, the device is to be packed so that it is protected against shocks and damp-
ness. Optimal protection is achieved when using the original packaging.
Notice!
Electrical scrap is a special waste product! Observe the locally applicable regulations re-
garding disposal of the product.
Connection
Interface
Max. wire length
Shielding
BCL 21/22 - Service
RS 232
10m
absolutely required, shield
meshing
BCL 21/MA 2 - Host
RS 485
1200m
absolutely required,
flexible leads as twisted pairs
Switching inputs 1+2
–
10m
not necessary
Switching outputs 1+2
–
10m
not necessary