![Leuze electronic AMS 384 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/leuze-electronic/ams-384/ams-384_technical-description_1883976051.webp)
Interbus interface
Leuze electronic
AMS 384
i
48
TNT
35/7-2
4
V
Notice!
For contacting
BUS IN
and
BUS OUT
, we recommend our ready-made Interbus cable (see
chapter 11.4.5 "Accessory ready-made cables for Interbus").
Attention!
The laser measurement system can be used to branch out the Interbus network.
The
continuing network
is connected via
BUS OUT
.
The integrated SUPI (Serial Universal Peripheral Interface) automatically detects whether
additional participants are connected to BUS OUT. Termination of BUS OUT is not necessary.
9.3
Interbus shielding and grounding concept
The cable shielding must be concentric and have the largest possible surface area on the
M 12 connector (thread).
The M 12 thread for BUS IN is connected to the functional earth (FE) inside the AMS 384
i
via an RC element (1M
Ω
|| 15nF). The M 12 thread for BUS OUT is conductively connected
to the housing and is thus directly connected to the functional earth (FE).
9.3.1
Interbus - voltage supply electrical connection
Figure 9.2:
Interbus - voltage supply
PWR
I/O 2
I/O 1
3
2
1
4
5
GND
VIN
FE
RWR connector (5-pin plug, A-coded)
Pin
Name
Remark
1
VIN
Positive supply v18 … +30 V DC
2
I/O 1
Input/output 1, by
default
:
Input
:
low (0 V) = laser on,
high (VIN) = laser off
3
GND
Negative supply voltage 0 V DC
4
I/O 2
Input/output 2, by
default
:
Output
:
low (0 V) = velocity limit value exceeded
high (VIN) = velocity limit value not met
5
FE
Functional earth
Thread
FE
Functional earth (housing)