![Leuze electronic AMS 358i Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/leuze-electronic/ams-358i/ams-358i_manual_1883975080.webp)
EtherNet/IP interface
77
AMS 358
i
Leuze electronic
9.7.6.3
Error delay - position
Attribute 3
The attribute specifies whether—in the case of an error—the position value immediately
outputs the value of attribute 1 (0 or last valid value) or the last valid position value for the
configured error delay time (attribute 4).
0 = error delay deactivated
1 = error delay activated
9.7.6.4
Error delay time - position
Attribute 4
Errors that occur are suppressed for the configured time. If no valid position value can be
ascertained during the configured time, the last valid position value is output. If the error
continues after the time elapses, the value configured in the "Position value in the case of
error" attribute (attribute 1) is output. The error delay time is specified in milliseconds [ms]
and must be a value between 100 and 1000.
9.7.6.5
Velocity in the case of error
Attribute 5
The attribute specifies which velocity is transmitted in the case of an error after the "error
delay time - velocity" elapses.
0 = last valid value
1 = value 0
9.7.6.6
Error delay - velocity status
Attribute 6
The attribute specifies whether the PLB status bit (implausible measurement value) is set
immediately or after the "error delay time - velocity" elapses.
0 = PLB status bit is set immediately
1 = PLB status bit is set with a delay
9.7.6.7
Error delay - velocity
Attribute 7
The attribute specifies whether—in the case of an error—the velocity value immediately
outputs the value of attribute 5 (0 or last valid value) or the last valid velocity value for the
configured error delay time (attribute 8).
0 = error delay deactivated
1 = error delay activated