EtherNet/IP interface
67
AMS 358
i
Leuze electronic
9.7.2.12 Warnings
Attribute 47
According to the CIP specification, warning messages are messages that signal the
exceeding of internal limit values but do not result in incorrect measurement values.
Status messages ATT, LSR and TMP are entered as warnings by the AMS 358
i
. For this
purpose, an area is reserved in the CIP spec. for device-specific data (bits 13-15).
9.7.2.13 Supported warnings
Attribute 48
Attribute 48 shows which warnings specified by the position sensor object are supported
by the AMS 358
i
.
Bit 13 =1; TMP warning is supported by the AMS 358
i
.
Bit 14 =1; LSR warning is supported by the AMS 358
i
.
Bit 15 =1; ATT warning is supported by the AMS 358
i
.
Bit 0 to bit 12 = 0
9.7.2.14 Warning flag
Attribute 49
The attribute evaluates the warnings supported in attribute 48 in an OR function (collective
warning).
9.7.2.15 Operating time
Attribute 50
As long as the AMS 358
i
is connected to power, the value is increased in increments of
1/10 hours. The value cannot be reset.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
–
–
–
–
–
–
–
–
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
ATT
LSR
TMP
–
–
–
–
–
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
–
–
–
–
–
–
–
–
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
1
1
1
–
–
–
–
–