DeviceNet interface
Leuze electronic GmbH + Co. KG
AMS 355
i
71
TNT
35/7-2
4V
Definition of the direction of movement depends on class 35, instance 1, attribute 12:
• Counting direction positive:
Measurement values increase when the reflector moves away from the AMS 355
i
. In
this case, the positive direction of movement is 0 in attribute 105.
• Counting direction negative:
Measurement values decrease when the reflector moves away from the AMS 355
i
. In
this case, the positive direction of movement is 1 in attribute 105.
9.6.3.22 Movement status
Attribute 106
The attribute indicates whether, based on the value, a movement > 100mm/s is registered.
0 = |curr. velocity| < 100mm/s
1 = |curr. velocity| > 100mm/s
9.6.3.23 Free resolution
Attribute 107
The free resolution refers to parameters 2048 and 2052 in attribute 15.
The entry is made in mm/1000 for parameter 2048 and in inch/100,000 for parameter 2052.
Example:
For a free resolution of e.g. 0.875mm, the value "875" must then be entered for
parameter 2048.
9.6.3.24 Offset
Attribute 108
Measurement value at the interface = measured di offset.
9.6.3.25 Laser diode status
Attribute 109
The attribute signals the status of the laser diode.
0 = Laser diode ON
1 = Laser diode OFF
9.6.3.26 Laser diode control
Attribute 110
This attribute is used to switch the laser on and off.
1 = Laser diode ON
0 = Laser diode OFF
9.6.4
Class 100 Display configuration
Object class 100 = 64
H