Diagnostics and troubleshooting
Leuze electronic
AMS 348
i
94
TNT
35/7-2
4
V
Use the up/down buttons
to scroll in the bottom half between various displays. The
contents of the scrollable pages are intended solely for Leuze for internal evaluation.
The diagnostics have no influence on the communication to the host interface and can be
activated during operation of the AMS 348
i
.
10.1.3
Expanded diagnostics
The
Expanded diagnostics
menu item is used for Leuze-internal evaluation.
10.2
General causes of errors
LINK LED for BUS IN and BUS OUT
A green/orange multicolor LED below the BUS IN and BUS OUT connectors indicates the
EtherNet/PROFINET connection status.
Green
continuous light
Power LINK green
- The link exists, the hardware connection to the next
connected participant is OK. The LED signals the
same status as "LNK0" and "LNK1" in the display.
Orange flashing
LINK LED flashing orange (ACT0/ACT1)
- Data is exchanged with the connected participants.
IO1
LSR
PLB
IO2 TMP
ATT
ERR
Pos. current: --------
Pos. min.:
--------
Pos. max.:
--------
ACT0
LNK0
LNK1
ACT1
LINK LED for BUS IN
LINK LED for BUS OUT