Fast commissioning / operating principle
Leuze electronic
AMS 348
i
10
TNT
35/7-2
4
V
3
Fast commissioning / operating principle
Notice!
Below, you will find a
short description for the initial commissioning
of the AMS 348
i
.
Detailed explanations for the listed points can be found throughout the handbook.
3.1
Mounting the AMS 348
i
The AMS 348
i
and the corresponding reflector are mounted on two mutually opposing,
plane-parallel, flat walls.
Figure 3.1:
Schematic illustration of mounting
Attention!
For error-free position measurement, there must be an unobstructed line-of-sight between
the
AMS 348
i
and the reflector.
3.1.1
Mounting the device
The laser is mounted on a vertical wall using 4 screws (M5).
Alignment is performed using 2 adjustment screws. Adjust so that the laser light spot is
positioned at the center of the reflector. The alignment is to be secured with the knurled nut
and locked with the M 5 nut.
Further information can be found in chapter 5.2 and chapter 5.3.
3.1.2
Mounting the reflector
The reflector is mounted on a vertical wall with 4 screws (M 5). The reflector is angled using
the included shims. Incline the reflector by approx. 1°.
Detailed information can be found in chapter 6.4.