![Leuze electronic AMS 348i SSI Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/leuze-electronic/ams-348i-ssi/ams-348i-ssi_original-operating-instructions_1883971060.webp)
PROFINET interface
Leuze electronic
AMS 348
i
SSI
57
TNT
35/7-2
4
V
9.5
PROFINET – General information on wiring
A Cat. 5 Ethernet cable should be used for wiring.
For the connection technology transition from M12 to RJ45, a "KDS ET M12 / RJ 45 W - 4P"
adapter is available that lets you connect standard network cables.
If no standard network cables are to be used (e.g. due to lacking IP… degree of protection),
you can use the "KS ET-M12-4A-P7-…" ready-made cable on the AMS 348
i
, see
table 12.4.5 "Accessory ready-made cables for PROFINET" on page 116.
The individual AMS 348
i
devices in a linear topology are connected with the
"KSS ET-M12-4A-M12-4A-P7-…" cable, see table 12.4.5 "Accessory ready-made cables
for PROFINET" on page 116.
For unavailable cable lengths, you can configure your cables yourself. For this purpose,
Leuze electronic offers a D-coded M12 round plug connector for Bus IN and Bus Out, see
table 12.4.3 "Accessory M12 connector" on page 114.
9.6
PROFINET – Cable lengths and shielding
Observe the following maximum cable lengths and shielding types:
Table 9.2:
Cable lengths and shielding
Connection
Interface
Max. cable length
Shielding
AMS – host
PROFINET-RT
100m
Absolutely required
Network from the
first AMS to the
last AMS
PROFINET-RT
The maximum segment length
must not exceed 100m for
100Base-TX Twisted Pair
(min. cat. 5)
Absolutely required