Display and control panel AMS 348i SSI
Leuze electronic
AMS 348
i
SSI
49
TNT
35/7-2
4
V
Position value submenu
Notice!
The parameters mentioned in the "Position value", "I/O" and "Other" sub-menus must be
set via the GSDML file of the AMS 348
i
. For test purposes, the parameters can be changed
directly on the AMS 348
i
via the display structure described below. After deactivation of the
parameter enable, however, the parameters stored in the GSDML file continue to be valid.
The parameters changed directly on the AMS 348
i
for test purposes are overwritten again.
Coding
Binary/gray
Specifies the output format of the measurement value.
Gray
Number of data
bits
24-bit/25-bit/26-bit
The measurement value can be displayed on the SSI interface in this data
width.
24 bit
SSI resolution
0.001mm / 0.01mm / 0.1mm / 1mm / 10mm / free resolution
The measurement value can be displayed in these resolutions.
The value of the free resolution is determined in the "Position value" sub-
menu in the "Value of free resolution" parameter.
0.1mm
Error bit
ON/OFF
This parameter determines whether an error bit is also attached to the
"number of data bits". The error bit is the LSB and is not converted in the
case of gray representation of the measurement value.
ON
Error bit function
The error bit can be set with the following status messages:
Overflow / intensity (ATT) / temperature (TMP) /laser (LSR) /
plausibility (PLB) / hardware (ERR)
In the case of multiple namings, the individual states in the error bit are
processed in an OR function.
Plausibility
(PLB)
Hardware
(ERR)
Clock frequency
50 - 79kHz / 80 - 800kHz
Selection of the clock frequency.
80 - 800kHz
Table 8.4:
Position value submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Measurement
unit
Metric/Inch
Specifies the units of the measured distances
Metric
Count direction
Positive/Negative
Positive: The measurement value begins at 0 and increases with increas-
ing distance.
Negative: The measurement value begins at 0 and decreases with
increasing distance. Negative distance values may need to be compen-
sated with an offset or preset.
Positive
Offset
Output value=measurement value+offset
The resolution of the offset value is independent of the selected "Reso-
lution position" and is entered in mm or inch/100. The offset value is
effective immediately following entry. If the preset value is activated, this
has priority over the offset. Preset and offset are not offset against each
other.
0mm
Table 8.3:
SSI submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard