Device parameters and interfaces
3
8
AMS 200
Leuze electronic
8
Device parameters and interfaces
8
.1
PROFIBUS
8
.1.1
General information
The AMS 200… is designed as a PROFIBUS-DP device. For this purpose the functionality
of the laser is defined via GSD parameter sets. The max. baud rate of the data to be trans-
ferred is 12 Mbit/s.
PROFIBUS, SSI and RS 2
3
2 interfaces can be used simultaneously as fully-fledged
interfaces. PROFIBUS and SSI interfaces are activated by default.
Notice
!
The PROFIBUS interface can be activated/deactivated via the display.
When the PROFIBUS is activated, the address set is visible on the display.
Figure 8.1: PROFIBUS activation
E
S
C
E
S
C
Measurement window with activated PROFI-
Display of the PROFIBUS address
Default: ON