Control panel display AMS 200…
Leuze electronic
AMS 200
25
TNT
3
5/7-2
4
V
6.2.2.
3
Status displays on the display
Input 1 or output 1 active
:
Function dependent on configuration (see also modules 4/5).
Input 2 or output 2 active
:
Function dependent on configuration (see also modules 4/5).
Warning laser prefailure message
:
Laser diode aged, device still functional; have replaced or repaired.
Temperature monitoring warning:
:
Above/below permissible internal device temperature.
Plausibility error
:
Implausible measurement value. Possible causes: light beam interruption, outside
of measurement range, permissible internal device temperature considerably
exceeded or traverse rate >10m/s.
Depending on the configuration, either zero or the last valid measurement value is
output at the interfaces.
Received signal warning
:
Laser emission window or reflector dirty. Clean surfaces.
Internal hardware error
:
The device must be sent in for inspection.
6.2.2.4
Bar graph
Indicates the
strength of the received laser light
.
The middle line represents the
ATT
warning threshold. The distance value remains
valid and is output at the interfaces.
If no bar graph is available, the
PLB
status information appears at the same time.
The measurement value has thus been assessed as being implausible. Depending
on the configuration, either zero or the last valid measurement value is output at the
interfaces.
6.2.2.5
Bus/interface info
Displays the set PROFIBUS address (default 126).
If the PROFIBUS is deactivated, this field is suppressed.
Displays the activated SSI interface. If the SSI interface is deactivated, this field is
suppressed.
Displays the activated Interbus interface. If the Interbus interface is deactivated, this
field is suppressed.
Displays the activated RS 2
3
2 interface. If the RS 2
3
2 interface is deactivated, this
field is suppressed.
6.2.2.6
Measured position value
The measured position value is displayed in the configured unit of measurement.
In the
metric
setting, the measurement value is always displayed in
m
with
3
decimal places
.
In the
inch
setting, the measurement value is always displayed in
in
with
1 decimal place
.