Function 

The AC-CPB display and control units are 
intended for access guarding with and without 
muting. Depending on version, they can be 
used to  

 

  reset the restart-interlock 

 

  display the OSSD state by illuminating the 

button (after configuring with SafetyLab) 

 

  if applicable, display the muting state by 

means of a LED indicator (A, B) 

 

  if applicable, evaluate 2 independent in-

duction loops as muting signals (B) 

The 3 devices are designed for direct 
connection to the 8-pin local socket of Safety 
Light Curtains and Multiple Light Beam Safety 
Devices of the COMPACT

plus

 series. AC-

CPB are mounted to a hard guard using 
supplied plastic strips  

 

Attention!

  

These display and control units must be 
mounted so that the entire danger zone 
can be viewed from the installation loca-
tion and so that any switched-on muting 
indicators can be clearly seen upon en-
try into the danger zone. 

Features 

 

  Acknowledge and override via illuminated 

button 

 

  Display of the muting state by LED indica-

tor 

 

  Simple mounting on hard guards by means 

of plastic strips 

 

  Connection via M12 plugs / sockets 

 