Leuze electronic
CMS 700i
– Contour Measurement System
Page 55
11 Technical data
Optical data
Operating range
Guaranteed operating range
Operating range
0,1 … 4,5m
Operating range, transparent media
0,1 … 1,75m
Operating range limit
Typical operating range
Operating range limit
0,1 … 6m
Beam spacing
5 mm
Measurement data
Minimum object height length light curtain
50 mm
Minimum object height length encoder
5 mm
Electrical data
Protective circuit
Polarity reversal protection
Short circuit protected
Transient protection
Supply voltage
100 … 263 VAC
Open-circuit current
250mA
Inputs/outputs selectable
None
Output current, max.
100 mA per switching output channel
Number of switching outputs
4
Number of switching inputs
4
Voltage type, outputs
DC
Switching voltage, outputs
24V
Voltage type, inputs
DC
Switching voltage, inputs
-3 .. 5V (LOW)
11 .. 30V (HIGH)
Timing
Readiness delay
60 sec
Response time per beam
10µs
Interfaces
Profinet
Functionality
Process data
Parameterization
Ethernet TCP/IP
Functionality
Process data
Parameterization
Connections control cabinet LSC-Box
Number of connections
9
Plug outlet
Axial
Connection 1
Type of connection
Ground terminal