Leuze electronic
CMS 700i
– Contour Measurement System
Page 53
9.3 Error codes of all interface
Value
Description
Comment
000
Without any error
System okay
001
General system error
002
General sensor error
System has a sensor error
003
General communication error
Communication disturbed or interrupted
004
General measurement error
Last measurement not valid
005 .. 019
Reserved
020
Error length sensor
General error length sensor
021
Communication error length
sensor
Communication to length sensor disturbed
or interrupted
022
Length sensor cleaning
Dirt on length sensor, cleaning required
023 .. 029
Reserved
030
Error width sensor
General error width sensor
031
Communication error width
sensor
Communication to width sensor disturbed or
interrupted
032
Width sensor cleaning
Dirt on width sensor, cleaning required
033 .. 039
Reserved
040
Error height sensor
General error height sensor
041
Communication error height
sensor
Communication to height sensor disturbed
or interrupted
042
Height sensor cleaning
Dirt on height sensor, cleaning required
043 .. 099
Reserved
100
Measurement dimension
Last object was too small in
≥ 1 dimension
101
Measurement plausibility
Raw data could not be evaluated correctly or
completely.
102 .. 255
Reserved