background image

Operating instructions

LCS-1

Teachable capacitive sensors with IO-Link

EN 2017/04 - 50136379

W

e

 r

eser

v

e

 the right t

o

 

make t

echnical changes

Содержание 50135720

Страница 1: ...Operating instructions LCS 1 Teachable capacitive sensors with IO Link EN 2017 04 50136379 We reserve the right to make technical changes...

Страница 2: ...Leuze electronic 2 LCS 1 2017 Leuze electronic GmbH Co KG In der Braike 1 D 73277 Owen Germany Phone 49 7021 573 0 Fax 49 7021 573 199 http www leuze com info leuze de...

Страница 3: ...operating modes 10 4 4 1 Configuration options 10 4 4 2 Medium present mode full teach 10 4 4 3 Medium not present mode empty teach 10 4 4 4 Switching point between medium present and medium not pres...

Страница 4: ...10 Eliminating faults 18 11 Maintenance 18 12 Repair 18 13 Decommissioning 18 14 Disposing 18 15 Technical data 19 Leuze electronic 4 LCS 1...

Страница 5: ...of icons The following icons are used in these instructions DANGER DANGER indicates an imminently hazardous situation with a high risk of fatal or severe injury if the situation is not avoided WARNING...

Страница 6: ...instructions you will also find the following documents on the Internet at www leuze com Data sheet of the respective device IODD file All necessary Leuze software components and the IODD can be down...

Страница 7: ...ct to the following EU directive 2014 30 EU EMC directive You can download the EU Declaration of Conformity at www leuze com 2 4 Manufacturer and maintenance Leuze electronic provides you with support...

Страница 8: ...ses are deemed as contrary to the intended use Leuze electronic shall not accept liability for damage resulting from such use 3 2 Obvious misuse The devices are not safety components and must not be u...

Страница 9: ...n nector for connection of the sensor cable LED Teach T2 Teach T1 24 8 50 87 3 M18 x 1 M12 x 1 Abb 1 Dimensioned drawing LCS 1M18P F05PNP M12 LT and LCS 1M18P F05NNP M12 LT with teach button LED Teach...

Страница 10: ...tions condensation film formation or soiling have little effect on the signal The switching point can be configured using the Medium present teach The time interval between two teach events can be any...

Страница 11: ...LCS 1 Product description 4 5 Technical accessories Suitable accessories can be purchased on the Leuze home page Selection of suitable connection cables Various mounting systems USB IO Link master 2...

Страница 12: ...or the mounting aid at the intended operating location Make sure that the connector on the rear of the sensor remains accessible Observe the minimum mounting distances LCS 1M18P LT LCS 1M30P LT Dista...

Страница 13: ...ignment Connection diagram Pin 1 UB 4 BK 1 BN 3 BU 2 WH 5 GY 1 3 4 5 teach pnp IO Link Pin 3 GND Pin 4 IO Link output or switching output Pin 5 Teach in NPN version Pin Pin assignment Connection diagr...

Страница 14: ...n the device is operated as a sensor the LEDs have the following display functions LED indicator Meaning Yellow steady light Sensor actuated Green steady light Sensor not actuated Lights up briefly Bu...

Страница 15: ...e taught in consecutively 9 1 Configuration via manual bridging Medium present teach Define object fill level for switching point Connect pin 5 to UB for 2 9 s If the LED goes out for approx 0 5 s and...

Страница 16: ...ach If the green LED flashes rapidly for approx 1 s the teach event has failed and must be repeated Medium not present teach Define object fill level for switching point Press button 2 for 2 9 s If th...

Страница 17: ...k and unlock the buttons on the sensor Switching point Configure the safety reserve between the measured capacitance and the taught switching point Sensor teach state Indicates the operating mode last...

Страница 18: ...devices do not require maintenance clean with a damp cloth as required 12 Repair The device is not designed to allow repair by the user If the device is defective take it out of operation and return i...

Страница 19: ...19 Leuze electronic LCS 1 Technical data 15 Technical data The technical data can be found in the data sheet The data sheet can be downloaded at www leuze com...