background image

Leuze electronic GmbH + Co. KG

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

[email protected]  •  www.leuze.com

We

 re

serve 

th

right

 t

o

 ma

ke

 c

h

an

ges 

• 

DS_LV46

3

XRA

_

e

n

_5013

5324

.f

m

Extra large operating ranges

Two, large, easy-to-read displays for the 
simultaneous display of the signal value 
and the switching threshold

Simple operation and easy-to-understand
menu functions for optimum configuration

Internal multiplex operation of up to six 
units 

Line teach or external transmitter activation  

Three different teach modes for fast sensor 
adjustment

One switching output and one analog 
output for each

One indicator diode for each of the two 
outputs 

Connection via cable or cable with M12 
connector

Up to 
5000mm

Up to 
1350mm

10 - 30 V

DC

Accessories:

(available separately)

Plastic fiber optics (KF, KFX)

Glass fiber optics (GF)

Ready-made cables (KB …)

Mounting device (BTU LV463)

UL

US

C

LISTED

IEC 60947...

IEC 60947...

Dimensioned drawing

A

Clamping lever for fiber optic cable (unlock in direction of arrow)

B

Connection for fiber optics receiver

C

Connection for fiber optics transmitter

35

10

Mounting accessories

With M8 connector

With cable

BTU LV463

 

Part no. 50120869

Electrical connection

5-pin connector

5-wire cable

multi funct

:

-  OFF
- Line teach
- Activation input
- Multiplex operation

Details 

 

Description of the subfunctions

NOTE

: Open lead wires must be connected to a terminal box.

LV463.XR

Long Range amplifier with analog output for fiber optics

   LV463.XR analog - 01

en

01

-2

01

6/

11

5

0

1

353

24

Содержание 50133985

Страница 1: ... outputs Connection via cable or cable with M12 connector Up to 5000mm Up to 1350mm 10 30 V DC Accessories available separately Plastic fiber optics KF KFX Glass fiber optics GF Ready made cables KB Mounting device BTU LV463 UL US C LISTED IEC 60947 IEC 60947 Dimensioned drawing A Clamping lever for fiber optic cable unlock in direction of arrow B Connection for fiber optics receiver C Connection ...

Страница 2: ...w LED Switching output active and signal in analog range Display 2 x 7 segment LED 4 digit Red signal strength Green switching threshold Mechanical data Housing ABS PC black red transparent PC cover Weight 50g with M8 connector 63g with 2000mm cable 70g with 150mm cable and M12 connector Connection type M8 connector 4 pin or 2000mm cable 4 x 0 25mm2 or 150mm cable with M12 connector 4 pin Fiber op...

Страница 3: ...0 5V 1 6V 0 10V configurable Connection technology Not specified Connection cable standard length 2000mm 4 5 wire 1 1 Devices with 1 x OUT and multifunction input 4 wire or 4 pin Devices with 2 x OUT and multifunction input 5 wire or 5 pin M8 M8 connector 4 pin 2 2 Not possible for devices with 2 x OUT and multifunction input 150 M8 Cable length 150mm with M8 connector 4 pin 2 150 M12 Cable length...

Страница 4: ...ay elements DIN rail TS 35 35mm x 7 5mm DIN rail TS 35 35mm x 7 5mm Spring mounted DIN rail mount The amplifier is mounted as shown on a TS 35 DIN rail while disconnected from voltage Alternatively the amplifier can also be mounted without a DIN rail using the mounting accessory and M3 screws Channel changeover slide switch Channel 1 CH1 Switching output Channel 2 CH2 Analog output Lever for fiber...

Страница 5: ...e increased or decreased by rocking In the PRG operating mode rock to navigate in the menu Button Press the rocker push button in the middle position to accept a setting made in the PRG operating mode Indicator Signal strength In the RUN and ADJ operating modes the display shows the current signal value In the PRG operating mode information on menu navigation appears on the display Switch position...

Страница 6: ...e If a scanning system is installed the switching output is active when an object is detected The status LED illuminates when the switching output is active don Switching output dark switching The switching behavior is the inversion of the light switching set ting SEnS SEL1 Sensitivity in switching point OUT1 Std hiGh Lo Std The sensitivity in the switching point is adjusted via the hysteresis Hig...

Страница 7: ...and if necessary alignment of the fiber optics recommended Error message thr Err The limit of threshold tracking is exceeded the sensor stops operating Cleaning and if necessary alignment of the fiber optics urgently necessary OFF dLY Switch off delay 0 off 1 9999 ms milliseconds 0 Switch off delay OFF Delay Individually adjustable from 1 9999ms Combination options Combining timing functions OFF I...

Страница 8: ... This subfunction is used for suppressing an offset signal that can result e g from crosstalk between transmitter and receiver at the fiber optic head To activate this function select YES and confirm the selection by press ing the rocker push button The current signal value is now set to 0 To perform another offset calibration the previous calibration must first be reset To do this select no and c...

Страница 9: ...e t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Rising edge Falling edge Active state of the switching output Set dela...

Страница 10: ...event of a faulty teach FAIL appears on the red display In this case the signal value may be too small and cannot be accepted as a teach value Table with minimum teach values as a func tion of the setting Check object and or placement and repeat event 2nd appears on the green display the red display shows the current signal value Place object 2 or object at distance 2 and press the rocker push but...

Страница 11: ...le settings value range Factory setting default Explanation tch SEL2 Teach mode analog OUT 2Pt tch 2Pt tch Teach analog output static 2 point teach The analog range is always set with two points The factory setting cannot be changed Point 1 corresponds to the start of the analog range Point 2 corresponds to the end of the analog range Aout RnGE Select analog range Devices with current output 4 20 ...

Страница 12: ...ermissible assignment of the analog range or Lo SPAn insufficient signal difference between start and end of analog range see note below Please repeat the process with corrected setting The assignment of the analog range can be adjusted later on With Rock to left the taught signal value appears on the red display and Value for end of analog range appears on the green display With Rock to right the...

Страница 13: ...ignal is applied prior to the teach Action begins with the rising edge tTeach 20 80ms Operating mode selector switch locked The teach event begins with the fall ing edge 1 Static 1 point teach The current signal value is taken over as the teach value with the falling edge 2 Static 2 point teach The current signal value is taken over as teach value 1 with the falling edge 3 Dynamic teach The sensor...

Страница 14: ...t teach T P T T T T T P T 2 point teach T P T T T T T P T T T Dynamic teach T P T T T T T P T T T T T Switching function OUT1 Light switching T P T T T T T T T P T Dark switching T P T T T T T T T P T T T Select analog range 0 10V 0 20mA T P T P T 0 5V 4 20mA T P T P T T T 1 6V no function T P T P T T T T T Characteristic output curve Rising characteristic curve T P T T T P T Falling characteristi...

Страница 15: ...ti funct multifunction inputs pin 2 ws WH are connected in parallel For settings see subfunctions Maximum 6 minimum 2 units 1 x master 1 5 slaves Each unit can be either a master mA or slave SL The master also requires the information on the number of units connected in parallel n 1 number of slaves Each slave also receives an individual address 1 5 max The master generates a timing signal on pin ...

Страница 16: ...n identical address from 1 5 Result Master and slaves have a time offset of 1 5 ms slaves with the same address operate synchronously Model 2 Synchronous operation through an external activation signal at the multi funct input pin 2 ws WH Subfunction setting Function InP SEL multi funct input SYnc PLc activation input multi funct activation input pin 2 ws WH Transmitter OFF Transmitter OFF Transmi...

Отзывы: