background image

Leuze electronic GmbH + Co. KG

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

[email protected] • www.leuze.com

We

 re

serve 

th

right

 t

o

 ma

ke

 c

h

an

ges 

• 

DS_LV46

3

B_en

_5

0126

178.

fm

Extremely short response time

Two, large, easy-to-read displays for the 
simultaneous display of the signal value 
and the switching threshold

Simple operation and easy-to-understand 
menu functions for optimum configuration

Internal multiplex operation of up to 
six units 

Line teach or external transmitter activation 

Three different teach modes for fast sensor 
adjustment

Switch for changing between light and dark 
switching

One PNP or NPN switching output

Indicator diode for operation and switching 
output

Connection via M8 connector, cable or 
cable with M12 connector

up to 
1700mm

up to 
450mm

10 - 30 V

DC

50 kHz

Accessories:

(available separately)

Plastic fiber optics (KF, KFX)

Glass fiber optics (GF)

Ready-made cables (KB …)

Mounting device (BTU LV463)

IEC 60947...

IEC 60947...

Dimensioned drawing

A

Clamping lever for fiber optic cable (unlock in direction of arrow)

B

Connection for fiber optics receiver

C

Connection for fiber optics transmitter

35

10

Mounting accessories

with M8 connector

with cable

BTU LV463

 

Part no. 50120869

Electrical connection

4-pin plug

4-wire cable

multi funct

:

-  OFF
- Line teach
- Activation input
- Multiplex operation

Details 

 

Description of the subfunctions

NOTE

: Open lead wires must be connected to a terminal box.

LV463B

High-speed amplifier for fiber optics

   LV463B - 02

en

02

-2

01

5/

01

5

0

1

261

78

Содержание 50126587

Страница 1: ... diode for operation and switching output Connection via M8 connector cable or cable with M12 connector up to 1700mm up to 450mm 10 30 V DC 50 kHz Accessories available separately Plastic fiber optics KF KFX Glass fiber optics GF Ready made cables KB Mounting device BTU LV463 IEC 60947 IEC 60947 Dimensioned drawing A Clamping lever for fiber optic cable unlock in direction of arrow B Connection fo...

Страница 2: ...ironmental data Ambient temp operation storage 10 C 55 C 20 C 85 C Protective circuit 4 4 2 polarity reversal protection 3 short circuit protection for all outputs 2 3 Protection class IP 50 NEMA 1 Standards applied EN 60947 5 2 Certifications UL 508 C22 2 No 14 13 3 5 5 These proximity switches shall be used with UL Listed Cable assemblies rated 30V 0 24A min in the field installation or equivale...

Страница 3: ... Close the transparent protective cover Controls and indicators DIN rail TS 35 35mm x 7 5mm DIN rail TS 35 35mm x 7 5mm Spring mounted DIN rail mount The amplifier is mounted as shown on a TS 35 DIN rail while disconnected from voltage Alternatively the amplifier can also be mounted without a DIN rail using the mounting accessory and M3 screws Slide switch switching output light LO dark DO switchi...

Страница 4: ...tput is active DO Switching output dark switching The switching behavior is the inversion of the light switching setting Rocker push button Set switching threshold Navigation in menu The rocker push button can be rocked to the right and to the left and pressed in the middle position Rock In the ADJ operating mode the switching threshold can be increased or decreased by rocking In the PRG operating...

Страница 5: ... threshold 2 point teach static the switching threshold is calculated at approxima tely midway between two signal values e g teach to two different objects or teach to the same object at two different distances from the probe Exa mple signal value 1 100digits signal value 2 400digits Switching threshold 280digits Actuate the rocker push button to or to make fine adjustments to the threshold Dynami...

Страница 6: ...ter settings mA n number Defines that this unit operates as master and a total of n sensors were wired in parallel Value range n 2 6 Example mA 4 means Unit is the master a total of four sensors are connected to one another via the multi funct multifunction input Slave settings SL n number Defines that this unit operates as a slave and has the individual address n Value range for address n 1 5 Exa...

Страница 7: ... t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT rising edge falling edge active state of the switching output se...

Страница 8: ...y In this case the signal value may be too small and cannot be accepted as a teach value Table with minimum teach values as a function of the setting Check object and or placement and repeat event 2nd appears on the green display the red display shows the current signal value Place object 2 or object at distance 2 and press the ro cker push button within one minute The second te ach value is accep...

Страница 9: ...5ms slaves with the same address operate synchronously Variant 2 Synchronous operation by means of an external activation signal at multi funct input pin 2 ws WH Setting for subfunction Function InP SEL multi funct input SYnc PLc activation input Slaves Slaves Master All multi funct multifunction inputs pin 2 ws WH are connected in parallel For settings see subfunctions Maximum 6 minimum 2 units 1...

Страница 10: ...with the falling edge 1 Static 1 point teach The current signal value is accepted as the teach value with the falling edge 2 Static 2 point teach The current signal value is accepted as teach value 1 with the falling edge 3 Dynamic teach The sensor begins scanning the signal values with the falling edge Notice The sensor has no timeout in teach mode until the next rising edge The teach event is co...

Отзывы: