![Leuze electronic 50038948 Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/leuze-electronic/50038948/50038948_original-operating-instructions_1883900063.webp)
Online commands
Leuze electronic
BCL 8
61
TN
T 3
5/7-
24V
Manual definition of the reference code
Command
’RS’
Description
This command can be used to define a new reference code in the BCL 8
by means of direct input via the serial interface. The data is saved in the
parameter set according to your input under reference code 1 or 2 and
stored in the working buffer for direct further processing.
Parameter
’RSyvxxzzzzzzzz’
y, v, x and z are placeholders (variables) for the actual input.
y
Def. reference code no.
’1’ (Code 1)
’2’ (Code 2)
v
Storage location for reference code:
’0’ RAM+EEPROM
’3’ RAM only
xx
Def. code type (see Command ’CA’)
z
Def. code information (1 … 30 characters)
Acknowledg
-
ment
’RSx’
x
Status
’0’ Valid ’Rx’ command
’1’ Invalid command
’2’ Insufficient memory for reference code
’3’ Reference code has not been saved
’4’ Reference code invalid
Example
Entry = ’RS130678654331’
(Code 1 (1), RAM only (3), UPC (06), code information)
UM_BCL8_de_50040581.book Seite 61 Montag, 24. Februar 2020 9:53 09