![Leuze electronic 50038948 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/leuze-electronic/50038948/50038948_original-operating-instructions_1883900029.webp)
Accessories/order codes
Leuze electronic
BCL 8
27
TN
T 3
5/7-
24V
Electrical connection MA 8-01
5.3.1
MA 8
-
01 - PWR IN HOST/RS485 - Voltage supply and RS 485
Figure 5.1: MA 8-01 - Pin assignment PWR IN HOST/RS485
Electrical data
Interface type
RS 485
Service interface
No MA 8
-
01 connected:
RS 232 with default data format,
9600Bd, 8 data bits, no parity, 1 stop bit
With MA 8
-
01 connected:
RS 485 replaces RS 232
Switching input/output 1 switching input, 1 switching output, each is programmable
Switching input:
10 … 30VDC
Switching output:
I
max
= 500mA
output voltage = operating voltage
Operating voltage
10 … 30VDC
Power consumption
Max. 0.5W
PWR IN HOST/RS485 (5-pin connector, A-coded)
Pin
Name
Comment
1
VIN
Positive supply voltage: +10 … +30VDC
2
B (N) RS 485 receive/transmit data
B-line (N)
3
GND Supply voltage: 0VDC
4
A (P) RS 485 receive/transmit data
A-line (P)
5
FE
Functional earth
Thread
FE
Functional earth (housing)
3
2
1
4
5
A (P)
GND
VIN
FE
B (N)
PWR IN
HOST/RS485
M12 connector
ATTENTION!
Degree of protection IP 67 is achieved only if the connectors and caps are screwed into
place!
UM_BCL8_de_50040581.book Seite 27 Montag, 24. Februar 2020 9:53 09