background image

www.lesterelectrical.com

1

00870E

LESTRONIC II BATTERY CHARGER

MODEL 07850

TYPE 36LC25-8ET

Specifications

AC Input:

105-128 Volts AC, 60 Hertz, single-phase, 13 Amps Max

DC Output:

36 Volts DC, 25 Amps tapering to 8 Amps at 45 Volts DC

Connections:

8½ ft. DC cord with connecting plug standard; optional plugs and cord lengths
available

Dimensions:

10-1/6 H x 8-11/16 W x 9-1/2 D

Mounting:

Set on shelf, wall mount with keyholes, or hang from ceiling securely.

PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS

For correct operation of the equipment, it is important to read and be familiar

with this entire manual before installing and operating the charger.

DO NOT DISCARD THIS MANUAL AFTER READING.

LOOK FOR THIS SYMBOL TO POINT OUT SAFETY PRECAUTIONS. IT MEANS:
BECOME ALERT—YOUR SAFETY IS INVOLVED.
  IF YOU DO NOT FOLLOW THESE
SAFETY INSTRUCTIONS, INJURY OR PROPERTY DAMAGE CAN OCCUR.

Features

Patented electronic timer monitors battery state of charge and automatically turns charger off at full charge.

Line voltage compensation achieved by flux oscillator ciruit applied to battery charger for high reliability "Minute Man" missile
standby applications.  Compensates automatically for AC supply voltage variations.  Supply voltage var 10% from
nominal = + 1% maximum battery voltage variation, decreasing to + ½% at finish rate with constant electrolyte temperature.
No taps or rate controls to set.

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Silicon diodes with inherent surge protection operation at a conservative percentage of their rating.

Convection cooled design for maximum reliability and minimum maintenance.

INTRODUCTION
The Lestronic II battery charger is designed to
recharge deep-cycle, lead acid batteries.  A
ferroresonant transformer is used to provide a highly
reliable, line compensating unit with a minimum of
moving parts, designed for long, trouble-free service.
A patented electronic timer turns the charger on and
off automatically.  This electronic timer determines
full charge of the batteries by measuring the rate at
which the battery voltage increases during charge.
When the voltage stops rising, the battery is fully
charged and the charger turns off.

INITIAL INSTALLATION
The AC line to which the charger is to be connected
must be capable of supplying 15 amperes to this
charger.

CAUTION:  TO REDUCE THE RISK OF FIRE,

USE THIS CHARGER ONLY ON CIRCUITS
PROVIDED WITH A MAXIMUM OF 20 AMPERE
BRANCH CIRCUIT PROTECTION (CIRCUIT
BREAKER OR FUSE), IN ACCORDANCE WITH
THE NATIONAL ELECTRICAL CODE, ANSI/NFPA
70, AND ALL LOCAL CODES AND ORDINANCES.

Содержание 07850

Страница 1: ...ions Supply voltage variation 10 from nominal 1 maximum battery voltage variation decreasing to at finish rate with constant electrolyte temperature No taps or rate controls to set Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate Silicon diodes with inherent surge protection operation at a conservative percentage of their rating Con...

Страница 2: ...OUNDING CONDUCTOR CAN RESULT IN RISK OF ELECTRIC SHOCK The conductor with insulation having an outer surface that is green with or without yellow stripe s is the equipment grounding conductor If repair or replacement of the electric cord or plug is necessary do not connect the equipment grounding connector to a live terminal Refer to a qualified service agent A temporary adapter as illustrated in ...

Страница 3: ... THE CHARGER TO OPERATE FOR MORE THAN 30 MINUTES WITH THE AMMETER READING 30 AMPS During charge the battery voltage increases gradually which causes the charge rate to decrease Good battery cells should each rise to approximately 2 5 volts DC which will allow the charge rate to taper to less than 8 amps Since each cell accepts charge at a slightly different rate normal charging with the ammeter re...

Страница 4: ...ed in storage self discharge sulfate to various degrees and lose capacity Repeated charging will generally result in the recovery of most of the battery s capacity though some permanent loss can be expected 5 Do not excessively discharge the batteries Excessive discharge can cause polarity reversal of individual cells resulting in complete failure shortly thereafter Limited use of new batteries wi...

Страница 5: ...ger is malfunctioning 2 Charger fuse blows The charger fuse assembly consists of a double ended fuse wire visible through a transparent cover mounted on the front panel Each half of the fuse wire serves as an individual fuse link which protects the charger in the event one or both rectifier diodes fail or a reverse polarity connection is made to the batteries Check the fuse assembly visually for a...

Страница 6: ...4973S DC CORDSET 12 2 108 GRAY SILICONE PLUG 18772S DC CORDSET 10 2 144 GRAY SILICONE PLUG 18773S DC CORDSET 10 2 250 GRAY SILICONE PLUG 08020S DC CORDSET 12 2 108 LESTER YELLOW PLUG 08607S DC CORDSET 12 2 108 W SB50 PLUG GRAY 10536S DC CORDSET 12 2 130 W SB175 PLUG GRAY 08313S PLUG ASSEMBLY SB50 GRAY 02957S PLUG ASSEMBLY SB175 GRAY 08045S DC RECEPTACLE ASSEMBLY FOR MOLDED RUBBER OR LESTER YELLOW ...

Страница 7: ...tory to the owner will be paid for by the owner All warranty work accomplished at the Lester factory will be completed with a reasonable time after receipt of defective items This warranty does not cover any semiconductor parts such as diodes which are vulnerable to electrical overloads beyond the control of Lester Warranty on parts not manufactured by Lester which include but are not limited to t...