Hardware  Installation 

Installation Steps 

This section will explain how to install PG5-0501-SFP-24 series. 

   

Caution:

 This device is intended for use indoor and at altitudes up to 2000 meters.   

   

Caution:

 The device is intended to be installed in an industrial control enclosure and panel 

 

Installation Steps 

Step 1

 

Unpack the industrial Ethernet switch from the original packing box. 

Step 2

 

Check if the DIN-Rail bracket is screwed on the industrial Ethernet switch.   

 

If  the  DIN-Rail  is  not  screwed  on  the  industrial  Ethernet  switch,  please  refer  to  the 

DIN-Rail Mounting

 section for DIN-Rail installation.   

 

If  you  want  to  wall  mount  the  industrial  Ethernet  switch,  please  refer  to  the 

Wall 

Mounting

 section for wall mounting installation. 

Step 3

 

To  hang  the  industrial  Ethernet  switch  on  a  DIN-Rail  or  wall,  please  refer  to  the 

Mounting Installation

 section. 

Step 4

 

Power on the industrial Ethernet switch and then the power LED light will turn on. 

 

If you need help on how to wire power, please refer to the 

Wiring the Power Inputs

 

section.   

 

Please refer to the 

LED Indicators

 section for LED light indication. 

Step 5

 

Prepare the twisted-pair, straight-through category 5 cable for Ethernet connection. 

Step 6

 

Insert one side of the RJ-45 cable into switch’s Ethernet port and on the other side 

into  the  networking  device’s  Ethernet  port,  e.g.  switch  PC  or  server.  The  Ethernet 

port’s  (RJ-45)  LED  on  the  industrial  Ethernet  switch  will  turn  on  when  the  cable  is 

connected to the networking device.   

 

Please refer to the 

LED Indicators

 section for LED light indication. 

Step 7

 

When all  connections  are  set  and the  LED lights  all  show  normal,  the  installation is 
complete. 

 

Содержание PG5-0501-SFP-24 Series

Страница 1: ...Leonton PG5 0501 SFP 24 Series PG5 0501 SFP 24 PG5 0501 SFP 24 T User Manual...

Страница 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Страница 3: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Страница 4: ...ysical Dimensions 4 Front Panel 5 Top View 5 LED Indicators 6 Ethernet Ports 7 Cabling 8 Wiring the Power Inputs 10 Wiring the Fault Alarm Contact 11 Grounding Note 12 Mounting Installation 13 DIN Rai...

Страница 5: ...designed to meet any needs for industrial automation outdoor application and harsh environments Software Features Network Redundancy STP RSTP MSTP ITU T G 8032 Ethernet Ring Protection Switch ERPS for...

Страница 6: ...d switching architecture 8K MAC Address Table Supports 9 6Kbytes Jumbo Frame 4Mbits memory buffer Power Input Redundant power DC 12 55V with connective 1 6 pin removable terminal block Max current 10A...

Страница 7: ...ly input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual Warning Labels The caution label means that you sho...

Страница 8: ...Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of PG5 0501 SFP 24 series W x D x H is 54mm x 99mm x 142mm Figure 2 1 PG5 0501 SFP 24 Series Physical Dimension...

Страница 9: ...wn below in Figure 2 2 Figure 2 2 The Front Panel of PG5 0501 SFP 24 Series Top View Figure 2 3 below shows the top panel of the PG5 0501 SFP 24 series switch that is equipped with one 6 pin removal t...

Страница 10: ...ready Off ERPS Owner Mode is not active RING Green On ERPS Ring Network is active and works well Flashing ERPS Ring works abnormally or misconfigure Off ERPS Ring Network is not active L A SFP Port 6...

Страница 11: ...devices connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing the straight through or crossover cabling See the figures as below for straight th...

Страница 12: ...45 port connections The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long The small form factor pluggable SFP is a compact optical tran...

Страница 13: ...C connector into the transceiver as shown below in Figure 2 9 Figure 2 9 LC Connector to the Transceiver To remove the LC connector from the transceiver please follow the steps shown below Step 1 Pres...

Страница 14: ...low in Figure 2 5 Figure 2 5 Pull Out from the SFP Module Wiring the Power Inputs Caution Please follow the below steps to insert the power wire Step 1 Insert the positive and negative wires into the...

Страница 15: ...of the terminal block connector as the picture shows below in Figure 2 8 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch o...

Страница 16: ...romagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices The grounding screw symbol is shown blow in Figure 2 15 Figure 2 15 Gro...

Страница 17: ...to install the DIN Rail on the switch Figure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to in...

Страница 18: ...w in Figure 3 2 Figure 3 2 Insert the Switch on the DIN Rail Step 4 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if t...

Страница 19: ...brackets on the top and bottom of the industrial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of...

Страница 20: ...lation Step 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section Step 4 Power on the industrial Ethernet switch and then the power LED light...

Страница 21: ...l as other cables Be careful when handling them so as to not trip over Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes located in the different faces o...

Страница 22: ...ssist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indicatio...

Отзывы: