background image

Bulletin G11N5

August, 2018

1360 Elmwood Avenue, Cranston, RI 02910 USA

Phone: 401.461.1200 Fax: 401.941.5310

Email: 

[email protected]

Web Site: http://www.leonardvalve.com

INSTALLATION ADJUSTMENT SERVICE

TM-1520B-2P, TM-1520B-2PS-LF

TM-2020B-2P, TM2020B-2PS-LF 

PARALLEL SYSTEMS

Note: IMPORTANT! Provide serial numbers for both valves when ordering parts!!

INSTALLATION

1. Type TM Parallel Systems are factory pre-assembled and

tested and include large and small thermostatic water
mixing valves which function as a system to meet both
high and low demand for tempered water.

2. System should be installed at a location where it can

easily be cleaned, adjusted or repaired.

3. System supplies must be connected as shown (Hot-left,

Cold-right). Exercise caution when soldering.

4. Flush

pipes

thoroughly

after

system

has

been

connected.

5. Assemblies installed on a recirculated hot water system

MUST

be

piped

according

to

LEONARD’S

REQUIRED PIPING METHOD #5

(see page 4).

6. Refer to page 3 of this bulletin for correct Setup

Instructions.

Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water.

CAUTION

All thermostatic water-mixing valves have limitations. They will not provide the desired
accuracy outside of their flow capacity range. Consult the capacity chart on page 12. Minimum
flow must be no less than as shown.

HOT

COLD

5"

CL

28"

2

0

4

0

°F

0

14

0

30

1

00

20

60

L EONARD

-10

°C

0

10

50

1

2

0

40

60

80

LEONARD VALVE  CO.

CRANSTON RI USA

TYP  TM

LF

LF

LEONARD VALVE CO.

CRANSTON RI USA

T YP   TM

LF

LF

39"

TM-2020B-2P, 2PS

TM-1520B-2P, 2PS

1
2

"

L

C

10

-10

20

0

40

14

0

°F

0

60

°C

50

LEONARD

20

40

R

30

1

2

0

10

0

60

80

LEONARD
THERMOSTATIC

C

H

ASSE
1017

LEONARD
THE RMOS TATIC

C

H

ASSE
1017

28"

38"

HOT

HOT

COLD

!

WARNING:

This

product

can

expose

you

to

chemicals including lead, which is known to the State
of California to cause cancer. For more information, go
to

www.P65Warnings.Ca.gov

Содержание TM-1520B-2P

Страница 1: ...mblies installed on a recirculated hot water system MUST be piped according to LEONARD S REQUIRED PIPING METHOD 5 see page 4 6 Refer to page 3 of this bulletin for correct Setup Instructions Maximum O...

Страница 2: ...less than shown see Flow Capacities page 12 If installed on a recirculated hot water system make certain the valve is piped according to Leonard s Required Piping Methods see page 4 REMEMBER THIS IS...

Страница 3: ...maximum temperature has now been set Test this temperature by holding a thermometer under the flow of water to be certain it is as desired LIMIT STOP MUST BE RESET AND RECHECKED EACH TIME HANDLE IS R...

Страница 4: ...all valve V2R and shut ball valve V2L at the mixing valve 9 Set outlet temperature of the mixing valve LVR to the same temperature as step 7 10 Turn off enough fixtures for a flow of at least 2 GPM 7...

Страница 5: ...RATURE WITH VALVE 1 IN THE FULL OPEN POSITION OPEN BALANCE VALVE 2 IN SMALL INCREMENTS i e 1 8 3 8 ETC UNTIL DESIRED TEMPERATURE IS ACHIEVED REMEMBER THIS IS A CONTROL DEVICE WHICH MUST BE CLEANED AND...

Страница 6: ...on corrosive cleaning solution DO NOT USE ABRASIVES Be certain thimble moves freely on port sleeve Note Driving ball on thimble must engage coil bracket in assembling 6 To disassemble bridge assembly...

Страница 7: ...OINTER ROD KIT 2 200Y CHECKSTOP KIT KIT 1 200Y PACKINGS GASKETS THERMOSTAT TGM 2 125 GROUP SCREEN 4724 TM 8 STEM O RING 4 LOWER STEM PACKING COIL SLEEVE 4733 2 EA STUD SPRING YELLOW 4742 TGM 1 200 POR...

Страница 8: ...DE AND RECORD NOTE AFTER INSTALLING NEW PARTS IT WILL BE NECESSARY TO RESET THE ADJUSTABLE HIGH TEMPERATURE LIMIT STOP ON EACH VALVE SEE PAGE 2 CHECKSTOP PARTS REPAIR KITS MU 4A RF MU 5A UPPER CHECKST...

Страница 9: ...rod nut MU 10B and pull bridge assembly off control rod 5 To clean submerge bridge assembly in clean water or non corrosive cleaning solution DO NOT USE ABRASIVES Be certain thimble moves freely on po...

Страница 10: ...RY TO RESET THE ADJUSTABLE HIGH TEMPERATURE LIMIT STOP ON EACH VALVE SEE PAGE 8 REPAIR KITS 10 04 125 SPRING LOWER STEM PACKING SWIVEL SWIVEL NUT 010 TM 02 BONNET STRAINER CAP 06 014 CAP PACKING 013 M...

Страница 11: ...BASIS SEE MAINTENANCE GUIDE AND RECORD NOTE AFTER INSTALLING NEW PARTS IT WILL BE NECESSARY TO RESET THE ADJUSTABLE HIGH TEMPERATURE LIMIT STOP ON EACH VALVE SEE PAGE 2 11 CHECKSTOP PARTS REPAIR KITS...

Страница 12: ...TY Leonard Valve Company hereinafter Leonard warrants the original purchaser that products manufactured by Leonard will be free from defects in material or workmanship under normal conditions of use w...

Отзывы: