background image

Acquaer Ltd. 

 

H-490

0, Fehérgyarmat, Szatmári út 11.

 

 

STAINLESS STEEL SUBMERSIBLE 

SEWAGE PUMP 

Instruction Manual 

XSP 

Содержание XSP9-7.5/0.25I

Страница 1: ...Acquaer Ltd H 4900 Fehérgyarmat Szatmári út 11 STAINLESS STEEL SUBMERSIBLE SEWAGE PUMP Instruction Manual XSP ...

Страница 2: ...ollection systems available Function and feature XSP series are the advanced and perfect sewage drainages at present time Compared with traditional sewage submersible pumps the XSP series is re designed the passage of flow and enjoys wider high efficiency areas can be used whole head without over loading and can safely run under large flow rate with high efficiency anti clogging impeller with big ...

Страница 3: ...e 0 5MI1 otherwise must check the fault 2 Check whether the power supply is conformed to the stipulation of nameplate before installation Pump must connect with earth to keep safe 3 Before installation must check whether the cable and plug is fracked scratched broken etc If they are faulty must consult dealer or technician qualified to replace them 4 Using iron thread or hoop to make the outlet an...

Страница 4: ...time Must take the pump out of the water and clean it and then make anti rust processing Troubleshooting Symptom Cause Corrective action Pump does not start 1 Too low voltage 2 Impeller blocked 3 Stator winding burn up 4 Capacitor damaged 5 Absent phase 3 phase 6 Too large resistance of cable 1 Adjust voltage to 15 of the rated 2 Remove obstacles 3 Repair 4 Replace capacitor 5 Check switch and cab...

Страница 5: ... to material or manufacturing faults will be rectified exclusively by our contracted workshops the seller has the right to remedy a defect in your vicinity or by the manufacturer if the latter is closer Any claims going beyond the provision of a guarantee are ruled out Any transport damage should be reported not to us but to the shipper in question since otherwise any compensation claims the shipp...