CENTRIFUGAL PUMP
Instruction Manual
ACm60 / ACm75 / ACm150 / ACm150B2
Страница 1: ...Acquaer Ltd H 4900 Fehérgyarmat Szatmári út 11 CENTRIFUGAL PUMP Instruction Manual ACm60 ACm75 ACm150 ACm150B2 ...
Страница 2: ... shall not be made by children without supervision Attention If the appliance or the supply cord is damaged it must be repaired by manufacturer its service agent or qualified person Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available Applications It is applica...
Страница 3: ...00 W 2 0 HP Inlet outlet diameter 1 1 1 1 1 25 1 2 2 Qmax 5 4 m3 h 6 0 m3 h 8 4 m3 h 30 m3 h Hmax 25 m 33 m 45 5 m 22 m Max Suction 8 m 8 m 8 m 8 m Gross weight 11 5 kg 13 4 kg 22 8 kg 20 7 kg Package 333x215x260mm 333x215x260mm 425x265x310mm415x225x285mm Implementation Standards IEC EN60335 1Householdandsimilarelectricalappliances safety Part1 General requirements IEC EN 60335 2 41 Household and ...
Страница 4: ...ounding to prevent short circuit for safety leakage protection switch should be equipped and be careful not to wet the power plug socket should be connected in damp proof area Do not touch the electric pump while working do not wash swim near working area or let livestock into the water to avoid accidents Avoid splashing pressured water to the electric pump as well as prevent the pump immersed by ...
Страница 5: ...alves in both sides of the bump should be turned off first and then empty liquids in the pump and pipelines so as not to be scalded Do not transfer any inflammable explosive or gasified liquids that beyond the stipulation Ensure the pump will not be accidently turned on while installing and maintaining if not used for a long time cut off the power first and then turn off valves in inlet and outlet...
Страница 6: ...ture POS Part POS Part 1 Pump body 10 Fan 2 Impeller 11 End plate 3 Mechanical seal 12 Capacitor 4 Seal holder 13 Capacitor box 5 Pump support 14 Terminal board 6 Bearing 15 Stator 7 Rotor 16 Bracket 8 Spring washer 17 Cable holder 9 Fan cover 18 O sealing ring ...
Страница 7: ...ards Install pipelines properly as stipulated in the manual and meanwhile conduct frost protection measures for the pipeline For the installation the inlet pipe should be as short as possible with the least turnings The pump should be installed in ventilated and dry environment It could be installed outside provided having proper covering to prevent rain and wind For pipeline use valves should be ...
Страница 8: ...in accordance with that of the water inlet to avoid too much water loss which will influence outlet performance 5 Pay attention to drop of water level while using the foot valve should not be above the water surface B1 6 In case the inlet pipe is longer than 10m or its lifting height exceeds 4m the pipe diameter should exceed diameter of water inlet of the pump 7 Ensure the pumped will not be affe...
Страница 9: ...ith power supply In case the working area of the electric pump is too far from the power supply power transmission lines should be of a heavier gauge otherwise the electric pump cannot work normally because the voltage drop is too dramatic A rubber extension cable shall be applied for the electric pump in case of outdoor use Check rotation of the motor three phase motor Check whether operation of ...
Страница 10: ...e Attention In case no water is discharged after being started for more than 5 minutes with water filled turn off the electric pump re fill water or check whether the inlet pipeline has leakages In case of any frost and ice damages please open the drain plug to empty water in the pump chamber When start up the pump again open the drain plug fill water and tighten it and then the pump is usable In ...
Страница 11: ...epair Impeller is jammed Turn rotating shaft of the fan blade terminal with screw driver to let it rotateflexiblyordemount the pump bodytoclear sundries Stator winding is damaged Replace windingcoils send to the maintenance point for repair The motor is in operation but no water is discharged Incorrect direction of pump rotation Inverttwo phase wiringsof the motor three phase motor The pump is not...
Страница 12: ...or winding is burned out The impeller is jammed or under overload operationfora longtime Clearsundries inthe pump chamber operate the pump under the rated flow as much as possible Incorrect grounding broken cable or the electric pump is hit by lightning Seek for the reason and replace winding coils Leakageof mechanical seal The mechanical seal is worn and torn by impurities Clearorreplacethe mecha...
Страница 13: ... to material or manufacturing faults will be rectified exclusively by our contracted workshops the seller has the right to remedy a defect in your vicinity or by the manufacturer if the latter is closer Any claims going beyond the provision of a guarantee are ruled out Any transport damage should be reported not to us but to the shipper in question since otherwise any compensation claims the shipp...