Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17
83
10
Parameter reference
10.2
Parameters of the communication module for slot MXI1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13882
C13883
C13885
Parameter | Name:
C13882 | EPL reset cycle counter
Data type: UNSIGNED_8
Index: 10693 = 0x29C5
EPL index: not available
The value "1" (TRUE) enables the code to reset the cycle counter (
After reset termination the code automatically assumes the value "0" (FALSE).
Setting range
(min. value | unit | max. value)
Lenze setting
0
1
0
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13883 | EPL response when "DataExchange" is quit
Data type: UNSIGNED_8
Index: 10692 = 0x29C4
EPL index: not available
Setting of the response when the "DataExchange" sate is quit.
A change in the monitoring response becomes immediately effective.
Selection list
(Lenze setting printed in bold)
0 No response
1 Trouble
3 Quick stop by trouble
4 Warning Locked
6 Information
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13885 | EPL data RPDO: error response
Data type: UNSIGNED_8
Index: 10690 = 0x29C2
EPL index: not available
The code controls the error response to failing PDO communication with a node. The failure is detected because
expected PDO data are missing.
Selection list
(Lenze setting printed in bold)
Info
0 Process data received
The data received last is continued to be used.
1 Clear process data
The data of all reception PDO channels is set to "0".
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT