S94P01B
23
5.2.2 Digital outputs
There are a total of five digital outputs (“OUT1” - “OUT4” and “RDY”) available on
the PositionServo 940 drive. These outputs are accessible from the P3 connector.
Outputs are open collector type that are fully isolated from the rest of the drive circuits.
See the following figure for the electrical diagram. These outputs can be either used
via the drives internal User Program or they can be configured as Special Purpose
outputs. When used as Special Purpose, each output (OUT1-OUT4) can be assigned
to one of the following functions:
• Not assigned
• Zero speed
• In-speed window
• Current limit
• Run-time fault
• Ready
• Brake (motor brake release)
Please note that if you assign an output as a Special Purpose Output then that output
can not be utilized by the User Program. The “RDY” Output has a fixed function,
“ENABLE”, which will become active when the drive is enabled and the output power
transistors becomes energized.
Digital outputs electrical characteristics
Circuit type
Isolated Open Collector
Digital outputs load capability
100mA
Digital outputs Collector-Emitter max voltage
30V
������
������
������
������
��
��
��
��