Malfunction
Fault
Possible causes
Remedy
Type Message
F
RFID read error (RFIR)
NFC communication interrupted
1. Connect and disconnect mains.
2. Repeat action.
3. If the error occurs again, please
contact the Lenze Service.
F
RFID write error (RFIW)
F
RFID data CRC invalid (PS02)
NFC communication interrupted
1. Load default setting.
2. Connect and disconnect mains.
3. Rewrite parameter set.
F
RFID data version invalid (PS04)
Incompatible software version
Update Lenze App or EASY Starter.
F
Missing mains phase (SU02)
A mains phase of a three-phase sup-
ply has failed. Reliable detection from
an utilisation > 50 % rated motor
power.
•
Check mains connection.
•
Check fuses.
F
DC bus overvoltage (OU)
DC-bus voltage too high
•
Increase deceleration ramp.
•
Reduce speed for great regenera-
tive loads.
•
Use brake resistor.
W
Electronics warning temperature (OH4)
Lacking or insufficient cooling.
Drive close to being disconnected due
to overtemperature (OH1)
Ambient temperature too high.
•
Check cooling.
•
Clean cooling ribs.
Ambient temperature must be in the
permissible range.
F
Electronics overtemperature (OH1)
F
Electronics overload (Ixt ) (OC9)
The Ixt overload test has been trig-
gered
•
Motor load too high.
•
Load cycles not complied with.
•
Increase deceleration ramp.
•
Reduce Imax.
•
Check dimensioning.
F
Electronics overcurrent (OC11)
Overcurrent limitation active
•
Reduce motor load.
•
Increase deceleration ramp.
F
Motor overcurrent (OC7)
The maximum current monitoring
function has been triggered.
Reduce motor load.
F
Motor short circuit (OC1)
Short circuit in the motor phases
Reset error. If the error occurs again
during restart, please contact the
Lenze Service.
F
Motor earth fault (OC2)
A motor phase has earth contact
F
Motor overload I2xt (OC6)
Motor thermally overloaded
•
Reduce motor load.
•
Check setting of the I2xt monitor-
ing function.
•
Increase deceleration ramp.
F
Brake resistor overload I2xt (OC12)
Too frequent and too long braking
processes
Increase deceleration ramp.
Lenze Smart motor without brake
resistor: DC-bus voltage too high
•
Reduce regenerative load.
•
Use brake resistor.
•
Increase deceleration ramp.
F
Internal error (DH69)
Various
Reset error. If the error occurs again
during restart, please contact the
Lenze Service.
F
Internal error (DF01)
...
Internal error (DF13)
Diagnostics and fault elimination
Malfunction
73
Содержание MSEMA 063-42 Series
Страница 2: ......
Страница 4: ...4...
Страница 18: ...Gewichte Transport Die Transportgewichte entnehmen Sie den Lieferpapieren Mechanische Installation Gewichte 18...