Basic safety instructions

DANGER!

Dangerous electrical voltage
Possible consequences: Death or severe injuries from electric shock

Any work on the device must only be carried out in a deenergized state.

After switching off the mains voltage, observe the signs on the product.

Product

The product must only be used as directed.

Never commission the product in the event of visible damage.

The product must never be technically modified.

Never commission the product before assembly has been completed.

The product must never be operated without required covers.

Connect/disconnect all pluggable terminals only in de-energized condition.

Only remove the product from the installation in the de-energized state.

Personnel
Only qualified and skilled personnel are allowed to work with the product. IEC 60364 and/or

CENELEC HD 384 define the qualifications of these persons as follows:

They are familiar with the installation, mounting, commissioning, and operation of the

product.

They possess the appropriate qualifications for their tasks.

They are familiar with all regulations for the prevention of accidents, directives, and laws

applicable at the location and are able to apply them.

Electrical connection
When working on energized products, comply with the applicable national accident

prevention regulations.
The electrical installation work must be carried out according to the appropriate regulations

(e.g. cable cross-sections, fusing, PE conductor connection). Additional information can be

obtained from this documentation.
This documentation contains notes about installation according to EMC regulations. Also

observe these notes for CE-marked products. The manufacturer of the system or machine is

responsible for adherence to the limits required in connection with EMC legislation.
Operation
Where appropriate, you must equip the system with additional monitoring and protective

devices. Comply with the safety regulations and other regulations applicable at the place of

operation.
After disconnecting the product from the supply voltage, do not touch live device parts and

power terminals immediately because capacitors may be charged. Observe the corresponding

information labels on the product.
Dirt or dust deposits impede the heat dissipation and cooling. Remove any such deposits

where appropriate at regular intervals.
Process engineering
The procedural notes and circuit details described are only proposals. It is up to the user to

check whether they can be adapted to the particular applications. Lenze does not take any

responsibility for the suitability of the procedures and circuit proposals described.

Safety instructions

Basic safety instructions

7

Содержание m850

Страница 1: ...Servo motors m850 synchronous servo motor Mounting and switch on instructions EN...

Страница 2: ......

Страница 3: ...Installation 18 Dimensions 18 Mounting 19 Electrical installation 20 Important notes 20 Preparation 20 Motor connection 21 Connection via ICN connector 21 Commissioning 27 Important notes 27 Before i...

Страница 4: ...her with the complete documentation of the product For safety rated attachments observe the enclosed operating instructions of the manufacturer The document includes safety instructions which must be...

Страница 5: ...er documentation with additional information Example EDKxxx see documentation EDKxxx Layout of the safety instructions DANGER Indicates an extremely hazardous situation Failure to comply with this ins...

Страница 6: ...personal injury and damage to property Observe all specifications of the corresponding documentation supplied This is the precondition for safe and trouble free operation and for obtaining the product...

Страница 7: ...cts comply with the applicable national accident prevention regulations The electrical installation work must be carried out according to the appropriate regulations e g cable cross sections fusing PE...

Страница 8: ...Directive 2014 30 EU The product is not a household appliance Instead it is a component that is intended exclusively for further use in the context of commercial or professional use as defined by EN...

Страница 9: ...ns The product does not provide any safety related functions A higher level safety system must be implemented Provide additional monitoring and protective equipment complying with the safety regulatio...

Страница 10: ...ds of operation with I Irated especially if there is a danger of blocking The integrated overload protection does not prevent overloading under all conditions The fuses are no motor protection Use a c...

Страница 11: ...uous standstill torque 5 11 Induced voltage Vin V 8 Brake data 8 2 Brake supply voltage 8 3 Electrical power input 8 4 Braking torque 10 Production data 10 2 Material number 10 3 Serial number 11 Bar...

Страница 12: ...Motor protection For the thermal sensors 1x PT1000 2x PTC the short designation PT1k 2PTC is given on the nameplate Product information Identification of the products Nameplates 12...

Страница 13: ...190 Motor length Short S Medium M Long L Speed 25 x 100 rpm 25 30 x 100 rpm 30 32 x 100 rpm 32 40 x 100 rpm 40 Degree of protection IP5x 5 IP6x 6 Cooling No cooling S Brake attachment No brake 0 Spri...

Страница 14: ...phase AC motors 1 Number of pole pairs for resolvers 2 3 4 Number of bits steps or increments per revolution 20 32 128 512 1024 2048 Supply voltage 5 V 8 V 15 V 24 V Interface or signal level Standar...

Страница 15: ...an overview of the elements and connections on the product Their position size and appearance may vary Output flange Output shaft Spring applied brake Motor connection Cooling Feedback Temperature mon...

Страница 16: ...olts or support plates Do not damage any components during transport Avoid electrostatic discharges on electronic components and contacts Avoid impacts Check the carrying capacity of the hoists and lo...

Страница 17: ...sible in the manufacturer s packaging In dry low vibration environment without aggressive atmosphere Protect against dust and impacts Observe the climatic conditions according to the technical data 4E...

Страница 18: ...o avoid tensions Mount belt pulleys sprockets or gear wheels as close as possible to the shaft shoulder in order to keep the bending load of the shaft and the bearing forces at a minimum level Tighten...

Страница 19: ...led manner according to manufacturer information Be sure to carry out mounting in a manner free from distortion Compensate minor inaccuracies by suitable flexible couplings Fastening Use screws with a...

Страница 20: ...e system or machine is responsible for adherence to the limits required in connection with EMC legislation Operation on an external inverter A max pulse voltage amplitude of Upk 1560 V at the motor te...

Страница 21: ...e value encoder Connection of temperature monitoring 2 ICN M23 connector Feedback connection Connection of temperature monitoring Motor ICN connector assignment Standard connection Power and brake One...

Страница 22: ...C 2 BD2 Holding brake DC AC 4 U Power phase U 5 V Power phase V 6 W Power phase W ICN M40 connector assignment 8 pole 1 2 W U V ICN M40 8 pole Contact Name Meaning BD1 Holding brake BD2 Holding brake...

Страница 23: ...ed 10 Schirm Encoder housing shield 11 Temperature monitoring PT1000 12 Temperature monitoring PT1000 ICN M23 connector assignment Incremental and SinCos absolute value encoder Hiperface 1 2 3 4 5 6 7...

Страница 24: ...V ICN M23 Hybrid for One Cable Technology OCT with digital absolute value encoder Contact Name Meaning U U Power phase U V V Power phase V W W Power phase W PE PE PE A BD1 Holding brake B BD2 Holding...

Страница 25: ...th digital absolute value encoder Contact Name Meaning U U Power phase U V V Power phase V W W Power phase W A BD1 Holding brake B BD2 Holding brake PE PE PE N Not assigned DSL1 VCC data DSL2 GND data...

Страница 26: ...n connecting the connector to the motor connector make sure that the aids to orientation pos 1 are facing each other 2 Tighten the box nut of the connector Motors with additional PE conductor connecti...

Страница 27: ...ence of the motor connection correct Is the contact of good electrical conductivity if a PE connection on the motor housing is used After a long period of downtime or after overhauling the motor check...

Страница 28: ...e motors against the ingress of foreign bodies Clean surfaces regularly If equipped with blower clean the air inlets regularly Brake The brakes are not accessible from the outside Maintenance work of...

Страница 29: ...operation of the drive system First check the possible causes of malfunction according to the 4Diagnostics and fault elimination 30 If the fault cannot be remedied using one of the measures listed pl...

Страница 30: ...ing flange during project planning Motor suddenly stops and does not restart Overload monitoring of the inverter is activated Check inverter settings Reduce load caused by longer acceleration times In...

Страница 31: ...A 22 2 No 274 UL 1004 6 Protection of persons and device protection Degree of protection EN EN 60529 EN 60034 5 IP54 Information applies to the mounted and ready for use state IP65 Temperature class I...

Страница 32: ...rating 1000 2000 m amsl Reduce rated output current by 5 1000 m Air humidity Without condensation Average relative humidity 85 Vibration resistance Operation EN IEC 60721 3 3 1995 A2 1997 3M5 only in...

Страница 33: ...6 40 7 80 6 30 10 0 12 2 Max current Imax A 15 0 28 0 42 0 23 0 45 5 66 0 Rated voltage Vrated V 330 330 320 340 330 330 Rated frequency frated Hz 330 330 330 270 270 270 Moment of inertia J kgcm 6 5...

Страница 34: ...Max current Imax A 64 0 87 0 112 Rated voltage Vrated V 340 330 345 Rated frequency frated Hz 250 250 210 Moment of inertia J kgcm 60 8 117 193 Efficiency 0 905 0 919 0 929 Torque constant Kt0 150 C...

Страница 35: ...ded exposure of substances to humans animals and the environment is excluded Lenze products are industrial electrical and electronic products and are disposed of professionally Both the mechanical and...

Страница 36: ...Lenze SE Postfach 101352 31763 Hameln Hans Lenze Stra e 1 31855 Aerzen GERMANY Hannover HRB 204803 Phone 49 5154 82 0 Fax 49 5154 82 2800 sales de lenze com www Lenze com 05 2021 4 0 www Lenze com...