Electrical installation
Electrical connections 931MxKx1
66
MA 13.1002 DE−EN DE/EN 1.1
4.3
Electrical connections 931MxKx1
X2 voltage supply
Contact pattern
Pin No. Value
Specification
1
0 V
2
PE
3
DC + 24 V / +42 V
Voltage supply
4
0 V
5
DC + 24 V / +42 V
Voltage supply
6
DC + 24 V
Auxiliary voltage supply
7
DC + 24 V
Brake voltage supply
8
GND
Brake enable
X1 RS232
Contact pattern
Pin no.
Signal
1
TxD
2
GND (ground)
3
RxD
X5 digital input, digital output (option)
Contact pattern
Pin No. Signal
Function
Specification
1
DC + 24 V
Control voltage DC + 24 V ± 10 %
2
DIN0
Digital input 0
Rated voltage
DC + 24 V
HIGH signal
DC 18 ... 30 V
LOW signal
DC 0 ... 4 V
Cycle time
Maximally 0.5
ms
3
GND
Reference potential for control voltage
4
DOUT0
Digital output 0
Output voltage
DC + 24 V
LOW signal
DC 0 ... 4 V
HIGH signal
DC 18 ... 30 V
Output current
Maximally 0.5 A
Cycle time
Maximally 0.5
ms
Short−circuit−proof
Содержание L-force 930 fluxxtorque