Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
95
3
Commissioning
3.10
PC manual control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.10.4
Manual jog
In the "Manual jog" mode, the drive can be traversed manually in a clockwise or anticlockwise
direction.
A change to the "manual jog" operating mode is made by selecting the correspondent option on the
Positioning
tab:
• The profile parameters stored in the parameter set for the basic "manual jog" function are used:
How to traverse the drive manually in inching mode:
1. If the inverter is still inhibited, enable the inverter via the
Enable controller
button.
• Please observe that the inverter will not be enabled if other sources of controller inhibit
(e.g. RFR terminal) are active.
If the inverter is in the "OperationEnabled" device status:
2. Press the
<< Left
or
Right >>
button (and keep it pressed) to traverse the drive with the
corresponding direction of rotation.
You can find detailed information on the "Manual jog" mode in the chapter entitled
"Basic drive functions" in the subchapter "
Parameters
Lenze setting
Info
Value Unit
Speed 1
(
)
360.0000 units/s
Manual jog speed
Acceleration
(
)
720.0000 units/s
2
For accelerating and decelerating, different values can
be set so that smooth starting and quick stopping of the
drive can be implemented.
Deceleration
(
)
720.0000 units/s
2
S-ramp time
(
)
0.000 s
In order to reduce jerking, the two ramps can be set in
such a way that they are s-shaped. This is done by
entering a relative S-ramp time.