15
Parameter reference
15.2
Parameter list
888
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00401
C00407
Parameter | Name:
C00401 | CANxInOut: Inversion
Data type: UNSIGNED_16
Index: 24174
d
= 5E6E
h
From version 02.00.00
This parameter serves to invert the control/status bits of the CAN port blocks.
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Active
Bit set = bit is inverted
... ...
Bit 15 Active
Subcodes
Lenze setting
Info
C00401/1
0x0000
Inversion of LP_CanIn1.bCtrl1_B0...15
C00401/2
0x0000
Inversion of LP_CanOut1.bState1_B0...15
C00401/3
0x0000
Inversion of LP_CanIn2.bIn1_B0...15
C00401/4
0x0000
Inversion of LP_CanOut2.bOut1_B0...15
C00401/5
0x0000
Inversion of LP_CanIn3.bIn1_B0...15
C00401/6
0x0000
Inversion of LP_CanOut3.bOut1_B0...15
C00401/7
0x0000
Inversion of LP_CanIn4.bIn1_B0...15
•
From version 15.00.00
C00401/8
0x0000
Inversion of LP_CanOut4.bOut1_B0...15
•
From version 15.00.00
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C00407 | LP_CanIn Mapping
Data type: UNSIGNED_32
Index: 24168
d
= 5E68
h
From version 12.00.00
Mapping for port blocks LP_CanIn1...4
• These settings are ORed with the mapping settings for the single words in
.
Setting range
(min. value | unit | max. value)
0
4294967295
Subcodes
Lenze setting
Info
C00407/1
0
:dwIn12 MapVal
C00407/2
0
:dwIn34 MapVal
C00407/3
0
:dwIn12 MapVal
C00407/4
0
:dwIn34 MapVal
C00407/5
0
:dwIn12 MapVal
C00407/6
0
:dwIn34 MapVal
C00407/7
0
:dwIn12 MapVal
•
From version 15.00.00
C00407/8
0
:dwIn34 MapVal
•
From version 15.00.00
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1