Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
847
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00160
C00161
C00162
Parameter | Name:
C00160 | Status determining error (16bit)
Data type: UNSIGNED_16
Index: 24415
d
= 5F5F
h
From version 06.00.00
Display of the short 16-bit error number of the status determining error
Structure of the 16-bit error number (bit coding)
Display range
(min. value | unit | max. value)
0
65535
Subcodes
Info
C00160/1
Status determining error (16-bit)
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00161 | LS_SetError_x: Error number
Data type: UNSIGNED_16
Index: 24414
d
= 5F5E
h
Setting of the error number for user error messages
Setting range
(min. value | unit | max. value)
0
65535
Subcodes
Lenze setting
Info
C00161/1
1
: Error no.1
C00161/2
2
: Error no.2
C00161/3
3
: Error no.3
C00161/4
4
: Error no.4
C00161/5
1
: Error no.1
C00161/6
2
: Error no.2
C00161/7
3
: Error no.3
C00161/8
4
: Error no.4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00162 | Error number masked
Data type: UNSIGNED_32
Index: 24413
d
= 5F5D
h
From version 13.00.00
Display of the 32-bit error number of the status determining error without error type
• The error number displayed here only contains the error subject area and error ID (lower 26 bits of the 32-bit error
number)
Structure of the 32-bit error number (bit coding)
Display range
(min. value | unit | max. value)
0
4294967295
Subcodes
Info
C00162/1
Subject area + Id statuserror
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1