15
Parameter reference
15.2
Parameter list
838
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00117
C00118
C00120
Parameter | Name:
C00117 | Status of brake output BD
Data type: UNSIGNED_8
Index: 24458
d
= 5F8A
h
Status message of brake output
Selection list
(read only)
Info
0 Inactive
Brake output is inactive
1 Active
Brake output is active
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00118 | DigOutX: Inversion
Data type: UNSIGNED_8
Index: 24457
d
= 5F89
h
The polarity of each digital output of the device can be inverted via this bit field.
Setting range
(min. hex value | max. hex value)
Lenze setting
0x00
0xFF
0x00
(decimal: 0)
Value is bit-coded: (
= bit set)
Info
Bit 0
Relay inverted
Relay inversion
Bit 1
DO1 inverted
Inversion of digital output 1
Bit 2
DO2 inverted
Inversion of digital output 2
Bit 3
DO3 inverted
Inversion of digital output 3
Bit 4
High current inverted
Inversion of high-current output
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C00120 | Setting of motor overload (I²xt)
Data type: INTEGER_16
Index: 24455
d
= 5F87
h
Operating threshold for the "OC6: Motor overload (I²xt)" error message
• The response for reaching the threshold can be selected in
• The current thermal motor load is displayed in
Motor overload monitoring (I2xt)
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
250.00
100.00 %
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100