15
Parameter reference
15.2
Parameter list
824
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00050
C00051
C00052
C00039/4
0.00 %
Fixed setpoint 4
C00039/5
0.00 %
Fixed setpoint 5
C00039/6
0.00 %
Fixed setpoint 6
C00039/7
0.00 %
Fixed setpoint 7
C00039/8
0.00 %
Fixed setpoint 8
C00039/9
0.00 %
Fixed setpoint 9
C00039/10
0.00 %
Fixed setpoint 10
C00039/11
0.00 %
Fixed setpoint 11
C00039/12
0.00 %
Fixed setpoint 12
C00039/13
0.00 %
Fixed setpoint 13
C00039/14
0.00 %
Fixed setpoint 14
C00039/15
0.00 %
Fixed setpoint 15
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00039 | Fixed setpoint x (L_NSet_1 n-Fix)
Data type: INTEGER_16
Index: 24536
d
= 5FD8
h
Parameter | Name:
C00050 | MCTRL: Speed setpoint
Data type: INTEGER_32
Index: 24525
d
= 5FCD
h
Display of the speed setpoint at the speed setpoint input of the motor control
Display range
(min. value | unit | max. value)
-120000
rpm
120000
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00051 | MCTRL: Actual speed value
Data type: INTEGER_32
Index: 24524
d
= 5FCC
h
Display of the actual speed value of the motor shaft
Note:
The displayed value only corresponds to the real actual speed value of the motor shaft if an encoder is connected to
the motor and the evaluation of the feedback signal has been set correctly ("Closed loop" operation).
In case of operation without speed feedback, the signal is calculated from the motor control and thus may not
correspond to the real actual speed.
Display range
(min. value | unit | max. value)
-120000
rpm
120000
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00052 | Motor voltage
Data type: UNSIGNED_16
Index: 24523
d
= 5FCB
h
Display of the current motor voltage/output voltage of the inverter
Display range
(min. value | unit | max. value)
0
V
1000
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1