15
Parameter reference
15.2
Parameter list
822
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00027
C00028
C00029
C00033
Parameter | Name:
C00027 | AINx: Gain
Data type: INTEGER_32
Index: 24548
d
= 5FE4
h
Gain for analog inputs
Setting range
(min. value | unit | max. value)
-100.0000
100.0000
Subcodes
Lenze setting
Info
C00027/1
1.0000
AIN1: Gain
C00027/2
1.0000
AIN2: Gain
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10000
Parameter | Name:
C00028 | AINx: Input voltage
Data type: INTEGER_16
Index: 24547
d
= 5FE3
h
Display of the input voltage at the analog inputs
Display range
(min. value | unit | max. value)
-10.00
V
10.00
Subcodes
Info
C00028/1
AIN1: Input voltage
C00028/2
AIN2: Input voltage
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00029 | AINx: Input current
Data type: INTEGER_16
Index: 24546
d
= 5FE2
h
Display of the input current at the analog inputs
• When the corresponding analog input is configured for current measurement (
= 1 or 2).
• When
is set = 2 (4 ... 20 mA), 0 ... 16 mA is displayed.
Display range
(min. value | unit | max. value)
0.00
mA
20.00
Subcodes
Info
C00029/1
AIN1: Input current
C00029/2
AIN2: Input current
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00033 | AINx: Output value
Data type: INTEGER_16
Index: 24542
d
= 5FDE
h
Display of the output value in percent of the analog input amplifier
• 100 %
≡
16384
≡
+10 V / +20 mA